30
ALKALINE BATTERY
FRAME
Installation Guide
Alkaline Battery and Power Detection LED (Side)
The Alkaline Battery Power LED on the side of the repeater gives you status on the external power connection and
indication on whether or not the batteries are being detected (as long the repeater is getting AC/DC power).
In the case that the repeater loses the external AC/DC power, this LED goes OFF. In this case, refer to the FRONT
LED status (Table 4), which gives other battery status information.
Note:
Alkaline Battery Frame is also available as a stand-alone accessory (P/N HKHN4003).
Do not attempt to recharge alkaline batteries. They are non-rechargable.
Table 3: Repeater – Alkaline Frame Battery and Power Detection LED (Side)
LED
Status
Batteries
Detection
AC/DC Status
Comments
Red (Fast)
Blinking
No Batteries
Detected
AC/DC
Connected
When the battery frame is empty
or the batteries are dead and AC/
DC power is connected.
Steady
Red
Batteries
Detected
AC/DC
Connected
Batteries are good and in place
and AC/DC is connected.
OFF
See FRONT
LED
AC/DC
Disconnected
When AC/DC is disconnected. In
this case, check the FRONT LED
for battery status.
Important