37
GET
T
IN
G S
T
ART
E
D
User Guide
REPEATER PROGRAMMING DEFAULT
VALUES
"Programmable Features Default Values" on
page 37 shows the default factory values that the
repeater has pre-programmed. These values can
only be customized by using the CPS software.
Table 6: Programmable Features Default Values
Feature
Values
Default
TX Timeout
1, 2 or 3 minutes
1 minute
TX Hangtime
(or Carrier
Delay)
Off to 50 seconds
3 seconds
Courtesy Beep
ON or OFF
OFF
Repeater ID
15 minutes, 30
minutes, after TX
hangtime, or OFF
15 minutes
On Battery
Back-Up
OFF, 15 minutes, 30
minutes, 45
minutes, 60 minutes
30 minutes
Low Battery TX
0 to 255 minutes
10 minutes
Number of
Channels
1 to 16
16
Reverse Burst
180 to 240
180
TX Power
2W
2W
TX BW
12.5 or 25.0 kHz
12.5 kHz
RX BW
12.5 or 25.0 kHz
12.5 kHz
2000018_B_PORS_en.book Page 37 Thursday, January 14, 2010 2:10 PM