P
R
E-
INST
AL
LAT
ION
CONSIDERATIONS
15
Installation Guide
ELECTRICAL REQUIREMENTS
AC/DC Power Requirements
The repeater comes equipped with a AC/DC
power supply, that operates from 110 Vac to 240
Vac at 50 Hz to 60 Hz. The following are the
electrical requirements:
Note:
The AC socket must be installed near the
equipment and must be easily accessible.
Consideration should be given to the
connection of the equipment to the supply
circuit and the effect that overloading of the
circuits might have on over current
protection and supply wiring. Appropriate
consideration of equipment ratings should
be used when addressing this concern
depending on where the equipment is
installed. It might be a requirement to plug
into a GFI protected receptable. Follow any
applicable local codes.
Site Grounding and Lightning
Protection
RPX- AC Electrical Requirements
AC Input to Repeater Power Supply
Current (A)
Voltage (V)
Power (W)
0.30
120 +/- 10%
36
0.16
220 +/- 10%
36
RPX- DC Electrical Requirements
DC Input to Repeater
Current (A)
Voltage (V)
Power (W)
1.10
12 +/- 10%
24
Proper site grounding and lightning
protection are vitally important
consideration, Failure to provide
proper lighting protection may result
in permanent damage to the
repeater equipment. Please refer to
"Appendix B: Repeater Lightning
Protection" on page 68 for basic
instruction.
!
C a u t i o n