MOTOROLA
MC68306 USER'S MANUAL
4- 13
EXIT
FETCH VECTOR
NUMBER
(DOUBLE BUS FAULT)
EXECUTE EXCEPTION
HANDLER
EXIT
(DOUBLE BUS FAULT)
(DOUBLE BUS FAULT)
ENTRY
SAVE CONTENTS
TO STACK FRAME
(SEE NOTE)
OTHERWISE
BEGIN INSTRUCTION
EXECUTION
OTHERWISE
BUS ERROR
BUS ERROR
BUS ERROR OR
ADDRESS ERROR
OTHERWISE
SAVE INTERNAL
COPY OF SR
S 1
T 0
(SEE NOTE)
NOTE: These blocks vary for reset and interrupt exceptions.
➧
EC28
➧
Figure 4-3. General Exception Processing Flowchart