Operation
ProStar MPPT Operator’s Manual
49
48
4.0
The amount of time between a green SOC indication and
load disconnect will depend on many factors including:
• rate of discharge (amount of load draw)
• capacity of the battery
• health of the battery
• LVD set-point
If the battery discharges to the LVD set-point the load will
disconnect and a solid red Battery Status LED indication will
be displayed.
General Load Control Notes:
Do not wire multiple ProStar MPPT load outputs together in
parallel to power DC loads with a current draw greater than
25 or 30A, depending on the ProStar MPPT model in use.
Equal current sharing cannot be assured and an over-load
condition will likely occur on one or more controllers.
Exercise caution when connecting loads with specific
polarity to a live load circuit. A reverse polarity connection
may damage the load. Always double check load
connections before applying power.
4.4 LED Indications
KEY:
G = green
G - Y - R = flashing sequencially
Y = yellow
G / Y = flashing together
R = red
G / Y - R = G and Y flashing together,
alternating with R flash
4.4.1. Power-up
Normal power-up: Status LED flashes
G
, then SOC LEDS
flash
G - Y - R
, then SOC LEDs indicate battery charge status
with a single battery status LED.
Failed bootload: Status LED flashes
G
, then SOC LEDS
flash
G - Y
and stop on solid
Y
.
4.4.2 Status LED
The Status LED indicates charging status and any exist-
ing solar input error conditions. The Status LED is on when
charging during the day and off at night. The Status LED will
flash red whenever an error condition(s) exists. Table 4.4 lists
the Status LED indications.
Color
Indication
Operating
State
None
Off (with heart-
beat¹)
Night
Green
On Solid
( with heart-
beat² )
Charging
Red
Flashing
Error
Red
On Solid
( with heart-
beat
2
)
Critical Error
¹ heartbeat indication flickers the Status LED on briefly every 5 seconds
² heartbeat indication flickers the Status LED off briefly every 5 seconds
Table 4.4. Status LED Definitions