AutoCreaser Pro 33A
Error Screens (Continued)
Lead Edge Sensor Cleaning.
Select the Tools menu on the Touchscreen Display, and then select the clean sensor
icon
The screen now shown is a visual indication of the strength of the Lead Edge Sensor beam.
The vertical indicator scale is divided into four sections, the position of the slider indicates
the strength of the beam. The strength of the beam is at its strongest towards the top half of
the indicator scale (green) and at its weakest towards the bottom half of the indicator scale
(red). Note the position of the slider on the indicator scale and then clean the sensors as
described on Page 44.
NOTE:-
This vertical indicator scale is repeated as a horizontal indicator scale on the right
hand side of the Touchscreen Display as shown below.
FLASHING (GREEN/BLACK) TO
INDICATE THAT THE SOFTWARE
IS INTERROGATING THE SENSOR
BEAM
SLIDER
INDICATOR SCALE
HORIZONTAL INDICATOR SCALE
Trouble Shooting
Page 44
CREASING
Error Screens (Continued)
To clean the lead edge sensors open the exit guard to expose the blade set. Using the
Sensor Cleaning Brush (Morgana part number 601-185), supplied in the dispatch kit, insert
the brush between the blade brushes and the top and bottom blades to reach the upper
and lower lead edge sensors. (See FIG.17 and FIG. 18 below). Move the brush backwards
and forwards several times across the sensors to clean them. Note the position of the slider
on the indicator scale; the slider should have moved nearer to the top of the scale,
indicating that dust has been removed from the sensors. This sensor cleaning operation
can be repeated again to see if the sensor beam strength can be further improved. The
Sensors can also be cleaned with a can of compressed air purchased from Farnell (Farnell
Part No. 166-3191), or an equivalent product.
Trouble Shooting
LEAD EDGE
SENSOR
SENSOR
CLEANING BRUSH
(601-185)
FIG. 18 (SECTIONED SIDE VIEW)
FIG. 17 (TOP VIEW)