CREASING
Error Screens (Continued)
To clean the lead edge sensors open the exit guard to expose the blade set. Using the
Sensor Cleaning Brush (Morgana part number 601-185), supplied in the dispatch kit, insert
the brush between the blade brushes and the top and bottom blades to reach the upper
and lower lead edge sensors. (See FIG.1 and FIG.2 below). Move the brush backwards
and forwards several times across the sensors to clean them. Note the position of the slider
on the indicator scale; the slider should have moved nearer to the top of the scale,
indicating that dust has been removed from the sensors. This sensor cleaning operation
can be repeated again to see if the sensor beam strength can be further improved. The
Sensors can also be cleaned with a can of compressed air purchased from Farnell (Farnell
Part No. 166-3191), or an equivalent product.