Section 3 - Installation and Wiring
Instructions in this section and others may require special precautions to ensure the safety of the
personnel performing the operations. Notes, Cautions and Warnings that may cause potential
safety issues are indicated throughout this manual by symbols, please refer to Page 3 of this
manual to view and familiarize yourself with these safety message symbols.
Figures 3.2 through 3.7 show the various housings and their dimensions.
Note:
Make sure to calibrate and bench check the instruments prior to installation. Also,
install all instruments in their intended application before making any electrical connections.
For DIN rail mounted instruments, allow enough room for pivoting instruments vertically on the
rail for removal in applications involving multiple banks of units. To remove the unit from the
DIN rail you will need a simple tool such as a straight blade screwdriver. Insert the blade of
the screwdriver into the cavity at the bottom of the locking mechanism and rotate it. This will
release the locking mechanism from the DIN rail and allow you to remove the unit.
Figure 3.1.
Terminal Designations
Terminal Designations
TB1
TB2
TB3
TB4
2W RTD / Resistance
3W RTD / Resistance
TB1
TB2
TB3
TB4
4W RTD / Resistance
TB1
TB2
TB3
TB4
POTENTIOMETER
TB1
TB2
TB3
TB4
2W RTD / Resistance
TB1
TB2
TB3
TB4
POTENTIOMETER
TB1
TB2
TB3
TB4
TB5
POTENTIOMETER
TB1
TB2
TB3
TB4
TB5
4W RTD / Resistance
TB1
TB2
TB3
TB4
TB5
3W RTD / Resistance
TB1
TB2
TB3
TB4
TB5
2W RTD / Resistance
TB1
TB2
TB3
TB4
TB5
THERMOCOUPLE / mV
TB1
TB2
TB3
TB4
TB5
+
-
TB1
TB2
TB3
TB4
THERMOCOUPLE / mV
+
-
TB1
TB2
TB3
TB4
TB5
2W RTD / Resistance
THERMOCOUPLE / mV
TB1
TB2
TB3
TB4
+
-
TB1
TB2
TB3
TB4
TB5
THERMOCOUPLE / mV
+
-
Sensor 1
Sensor 1
Sensor 2
Sensor 2
TB1
TB2
TB3
TB4
TB5
3W RTD / Resistance
-PS
+PS
-PS
+PS
STZ HPP
STZ
DIN
STZ HP
TB1 TB2 TB3 TB4 TB5
TB2
TB3
TB4
TB1
-PS
+PS
TB1 TB2 TB3 TB4 TB5
STZ HPP (4 Terminals) Input Connections
STZ HP and STZ DIN (5 Terminals) Input Connections
Note: STZ [HPP] (see figure 3.4) – When using two input sensors, Sensor 1
can be configured as 2-wire or 3-wire sensor. Sensor 2 is then restricted to
a 2-wire sensor.
Note: STZ [DIN] (see figure 3.2) - When
using two input sensors you are
limited to 2-wire and/or 3-wire sensors.
4-wire sensors (RTDs) cannot be used.
Note: STZ [HP] – When using two input
sensors you are limited to 2-wire
and/or 3-wire sensors. 4-wire sensors
(RTDs) cannot be used.
GND
Note: *GND is Case Ground terminal
used for -AIS option only.
Functional Safety Dual Input Smart HART® Temperature Transmitter
STZ
SECTION 3