GARMIN G1000 ANNUNCIATIONS AND WARNING LIGHTS - CONT’D
ANNUNCIATION
FUNCTION
ANNUNCIATION
COLOR
ANNUNCIATION
TRIGGER
ACTION
WHEN ON
ACTION
WHEN OFF
SPEEDBRAKE
WHITE
WHITE SPEED BRAKE DIS-
PLAYED ON G1000.
STEADY WHITE
“SPEEDBRAKE”
OFF WHEN
SPEEDBRAKES
ARE
RETRACTED
ALTERNATE AIR
AMBER
AMBER ALTERNATE AIR when
ALTERNATE AIR handle is manu-
ally pulled out or when Automati-
cally opened (Induction Air system
Blockage).
STEADY
AMBER
“ALTERNATE
AIR”
OFF WHEN AL-
TERNATE AIR
HANDLE IS
PUSHED IN
PROP DEICE
AMBER
If system is operating properly, the
GREEN PROP DEICE switch
lamp is illuminated, and the
G1000 shows no annunciation.
Amber PROP DEICE FAIL if the
PROP DEICE switch is in ON po-
sition with Green PROP
DEICE switch lamp illuminated,
but PROP DEICE system has
failed. NOTE: PROP DEICE is
only an option for aircraft without
TKS installed.
STEADY
AMBER
“PROP DEICE
FAIL”
OFF WHEN
PROP DEICE
SWITCH IS
SELECTED OFF
PITOT HEAT
AMBER
If system is operating properly, the
GREEN Pitot Heat switch lamp is
illuminated, and the G1000 shows
no annunciation. AMBER PITOT
HEAT FAIL if the PITOT HEAT
switch is in ON position with
Green PITOT HEAT switch lamp
illuminated, but Pitot Heat system
has failed.
STEADY
AMBER
“PITOT HEAT
FAIL”
OFF WHEN
PITOT HEAT
SWITCH IS
SELECTED OFF
ALTERNATOR
FAIL
RED
RED ALTERNTR FAIL when Al-
ternator output goes to zero, or
when Field shorts. NOTE: Volt-
meter on MFD Display flashes
YELLOW when bus voltage drops
below
~
@24.5VDC whether al-
ternator has failed or not.
STEADY RED
“ALTERNTR
FAIL”
OFF WHEN
ALTERNATOR
OUTPUT IS
NORMAL
START POWER
RED
RED START POWER
displayed ON when starter is en-
gaged
STEADY RED
“START
POWER”
OFF WHEN
STARTER IS
NOT ENGAGED
EMERGENCY
BUS
AMBER
AMBER EMRGENCY BUS when
EMERGENCY BUS switch is se-
lected ON. Green lamp on Emer-
gency Bus switch when switch is
selected ON
STEADY RED
“EMRGENCY
BUS”
OFF WHEN
EMERGENCY
BUS NOT
ENERGIZED
DOOR OPEN
RED
RED DOOR OPEN Displayed on
G1000 when either cabin door(s)
or baggage door is not shut.
STEADY RED
“DOOR OPEN”
OFF WHEN
ALL DOORS
ARE SHUT
LOW BOOST
PUMP
WHITE
LOW BOOST: GREEN lamp illu-
minated on LOW BOOST Switch.
WHITE low boost Illuminated on
Annunciation.
STEADY WHITE
“LOW BOOST
PUMP”
OFF WHEN
LOW BOOST
PUMP SWITCH IS
SELECTED OFF
LOW FUEL
RIGHT OR LEFT
AMBER
AMBER when fuel quantity
usable is ~10 U.S. Gallons
N/A
N/A
LOW FUEL
RIGHT OR LEFT
RED
RED when fuel quantity usable is
> 6- 8 U.S. Gallons
N/A
N/A
HI BOOST PUMP
AMBER
AMBER HI BOOST Displayed on
G1000. NOTE: The HI BOOST
switch has a thumb lock- out to
prevent accidental operation in-
stead of a green lamp.
STEADY
AMBER
“HI BOOST
PUMP”
OFF when
HI BOOST PUMP
switch is
selected OFF
Revision A: 08-18-2017
Содержание M20V Acclaim Ultra
Страница 3: ......
Страница 5: ...MOONEY M20V BLANK...
Страница 7: ...MOONEY M20V ACCLAIM ULTRA INTRODUCTION BLANK...
Страница 17: ...MOONEY M20V ACCLAIM ULTRA INTRODUCTION ORIGINAL ISSUE 03 16 2017 x BLANK...
Страница 19: ...MOONEY M20V ACCLAIM ULTRA SECTION I GENERAL 1 2 ORIGINAL ISSUE 03 16 2017 AIRPLANE FLIGHT MANUAL BLANK...
Страница 33: ...MOONEY M20V ACCLAIM ULTRA SECTION II LIMITATIONS 2 2 AIRPLANE FLIGHT MANUAL ORIGINAL ISSUE 03 16 2017 BLANK...
Страница 175: ...MOONEY M20V ACCLAIM ULTRA SECTION VI WEIGHT AND BALANCE 6 2 AIRPLANE FLIGHT MANUAL ORIGINAL ISSUE 03 16 2017 BLANK...
Страница 253: ...MOONEY M20V ACCLAIM ULTRA SECTION IX SUPPLEMENTAL DATA 9 4 AIRPLANE FLIGHT MANUAL ORIGINAL ISSUE 03 16 2017 BLANK...
Страница 255: ...MOONEY M20V ACCLAIM ULTRA SECTION X SAFETY INFORMATION 10 2 AIRPLANE FLIGHT MANUAL ORIGINAL ISSUE 03 16 2017 BLANK...