© MOOG 2019
This document is subject to MOOG INTELLECTUAL AND PROPRIETARY INFORMATION LEGEND . The details are on page II.
58
MRJ06301
Range L
Range L changes
the value of all profile points by a
percentage of the difference between the thickest and
thinnest points. The value of the thickest profile point
remains constant during a
Range L
change.
Range L
can vary between
–3276.7% and +100%.
Range L
may be changed until the thinnest profile point reaches
zero. Use the
Rotaly Knob
and
SET
to change the
Range L
setting. The percentage
Range
L
change will
remain displayed after being
Set
. When the
Entry
Knob
is turned again the new
Range L
entry will start
at zero using the current display as a reference. If the
Rotaly Knob
is accidentally moved and the displayed
Range L
value changed, it will revert to its former value
if
SET
is not pressed and the
Cursor
used.
Range L
has the effect of allowing container weight
changes while retaining the containers maximum wall
thickness distribution pattern.
Figure 2-16 0% Range L
Figure 2-17 shows the effect of a
Range L
decrease of
–20.0% from the
Range L
value of 0% in Figure 2-16.
To make the change easier to visualize, reference lines
drawn between the figures starting at four different par-
ison wall thickness program points have been included.
Range L
will use the thickness parison wall thickness
program point as a reference and will not change its
thickness. The
Range L
change will be largest at the
minimum parison wall thickness point, and proportion-
ately less at the intermediate parison wall thickness
points.
Figure 2-17 (-)20.0% Range L
The highest thick-
ness will be fix