2-4-5. F4: Monitor Mode
Mode obtained by pressing the
F4
key.
Display
Available at all times. But not available to change manual
mode when profile is running.
Manual Mode is used to display and/or control the positions
of the tooling actuator (DCDT) and the value of the servo-
valve input current as well as the Output ON/OFF functions.
Auto Mode ONLY displays the above information.
Commands
The
Cursor
is used (or directly touch) to move to the various
commands only in MANUAL mode. The SET Key is inactive.
The displayed values reflect the actual positions or servo-
valve current. (or Spool position in EFB mode)
Output
There are 6 output commands which may be changed with
the
Rotaly Knob
. Counter-clockwise rotation produces a 0
(OFF) and Clockwise rotation a 1 (ON).
Figure 2-29 F4: Monito screen
The functions controlled are: (1) End of Filling; (2) End of Extrusion; (3) Point out; (4) End of Start slope;
(5) Ready; (6) Alarm.
Input
There are 7 input commands to monitoring the following functions: (1) Start, (2) Die gap; (3) Reset; (4)
Stop; (9) Start Slope, (10) Emergency, (11) Temp OK. (not use 5 to 8)
Core check
When the display
Cursor
points to “
Core check
”, it is possible to control the tooling position in closed loop
using the
Rotaly Knob
between 0 to over 3276.7%. (100% = Span position) *This parameter can not be
changed with 10 key.
Open command
When the display Cursor points to “
Open command
”, it is possible to control the value of the servovalve
input current with the Rotaly Knob. *This parameter can not be changed with 10 key.
USE OF
“Open command” MAY RESULT IN DAMAGE TO THE TOOLING.
When the servovalve input is equal to any value other than those in the Zero range, servovalve oil flow
will cause the tooling cylinder to move. The tooling actuator will stop only when the servovalve input current
is within a very narrow band in the Zero current range. If the tooling actuator stops due to contact with the
die and mandrel, very high forces may be exerted on the tooling, possibly causing damage. It is highly
recommended that the hydraulic pressure be reduced to a low value to prevent possible damage.
To prevent inadvertent damage, setting the Open command to
“Disable” in Machine setup display
(