Validation
Checking the pulse function
On RC6 novo the heart rate is displayed in Monark
novo Display Unit. The heart rate can also be
displayed in other external device.
While the patient rests, with the chest belt on, compare
the displayed heart rate (Monark novo Display Unit,
PC or other) with the manually taken pulse. If it does
not correspond, check the chest belt contact area and
if necessary moisten the electrode surfaces with water.
The following controls ensures that the bike works
for daily use.
• Checking the pulse function
• Check the adjustment / zero of the scale
• Check the braking force
• Test by pedalling and check that a reasonable
RPM is obtained - verify by a clock. Feel if the
pedals move smoothly. Listen for unusual sounds.
Adjust if necessary.
• Adjust the handlebar and saddle and make sure
they are securely attached and that the adjustment
is working properly.
• Make sure the support legs are in position by
rocking the bike. Tighten if necessary.
If something unusual is found during the daily
inspection that you cannot resolve, please call
customer service.
Scale adjustment
First check that the brake belt is loose, see
Fig:
Checking loose brake belt.
If not, move the pendulum
to 4 kp and hold it there a while to loosen it. Then
check that the pointer on the pendulum is aligned
with the 0-index (3) on the scale (2). If not, you need
to adjust the scale. Loosen the pole screw (1) (do not
unscrew it completely), and adjust the scale so that the
0-indices and indicators are consistent. Tighten the
pole screw again as the scale is locked into position.
See
Fig: Scale adjustment.
Fig: Scale adjustment
1) Screw
2) Scale
3) 0-index
Fig: Checking loose brake belt