RC6 novo
28
Symptoms
Probable Cause / Corrective Action
LED does not light up
• No current in the wall outlet. Check the fuses.
• Power switch off on the bike / Monark novo control unit.
• Correct power adaptor? Check that the power adaptor information (voltage,
current, polarity, AC / DC) in section "Product information" complies with
the power adaptor which is used.
• Check cables and connections.
No connection to PC
• Check cables (connections and type)
• Right "cmd type", see section "Connection to controller"
• Right COM-port (PC software or similar).
• Drivers missing when using the USB-serial adaptor
No workload
• Pendulum is stuck. Contact service centre for action / replacement.
• Check that the pedal speed is higher than 30 RPM and recorded. No workload
is put on if the actual pedal speed is lower than 30 RPM. See in Monark test
software: - ’Monark Ergomedic’ - ’Service program...’ - ’Service Setup...’ -
’Pedal measurement’. The default setting is 30 RPM but can be adjusted to
the desired value.
• Check calibration.
• Check that the brake belt is suspended in the spring and located right on the
flywheel.
No heart rate displayed
• A chest belt is already connected and active at the moment to other device.
• Check that the battery is alright in the chest belt, moisten your thumbs and
click on the electrodes, a
low
clicking sound will be heard at the battery cover,
(not chest belts with Bluetooth technology) alternatively that the heart rate is
displayed in the PC software.
• If no pulse is not detected despite new battery, try to take the battery out from
the chest belt transmitter and let it be out for six minutes. If it does not work
anyway, contact your dealer.
• Make sure the belt fits correctly on the test person, see
Fig: Placement chest belt
in section "Pulse settings", and that the strap is sufficiently tightened. Moisten
the electrodes, in severe cases it may be necessary to use gel alternative, one
drop of dish washing liquid mixed in water. Pulse signal strength varies from
person to person. Try the belt with a person known to have a good pulse
wearing a chest belt.
Irregular heart rate
• Use an external device (eg. pulse clock or an app in the cell phone) to check if
it also has an irregular pulse. If this is the case, there is probably disturbance
in the room. The disturbance may be electronic fields from power cables,
elevators, lamps etc. or other electronic devices which are too close (eg. cell
phones). Move the bike to a different location in the room or change rooms.
Even synthetic fabrics can create static electricity that interferes with
heart rate signal.
If the HR remains irregular at work the person's health
should be examined.
No RPM reading
• Check cable.