Page 14
@BAUD
Will display the BAUD rate in kbyte/sec
@ENET
Will show the Ethernet Address settings. IP Address, Sub net
mask and Gateway Address
@OUTPT
POS or NEG
Select the polarity of the pulse output.
@DSPLR
HALF, 1_SEC, 1.5_S
This sets the maximum display update rate to ½, 1 or 1½ second.
@SERNO
View the serial number of the unit.
@PASSC
xxxxx
Set this to 00000 for no passcode. Otherwise the user must
enter the xxxxx passcode to enter the menu.
If a user tries to enter too many characters, or enters illegal data, the instrument will respond with
Err
and will abort
the process. If the command is successfully executed, the instrument will again send the
OK
message.
7.0
SPECIFICATIONS
Speed Range
5 RPM to 999,990 RPM
(speeds below 5 RPM are possible with multiple pulses per revolution)
Input Frequency Range
0.083 Hz to 250 KHz
Totalizer / Counter
Display Range: 0.001 to 99,999
100,000 – 999,990 (only top 5 digits are shown -- x10)
Maximum # of counts of 16,777,216 even with a 0.001 scale
Input Configuration
and
Voltage Range
Universal inputs: 1 to 9,999 pulses per revolution
Front panel push button programmable
TTL input and 1.1 V to 50 Vac signals – Opt: -1 to -50 Vdc
Accuracy
±0.001% of reading or ±1 displayed resolution (Standard Gate)
±0.01% of reading or ±1 displayed resolution (Fast Gate)
Resolution
Fixed Range Mode
Auto Range Mode
1 RPM (5 to 99,999 RPM)
Up to 0.001 RPM
10 RPM (100,000 to 999,990 RPM)
Display
5 digits 0.56 inch high red seven segment LED
Display Update
Menu selectable between: 0.5 second above 120 RPM, 1 Second above 60 RPM, 1.5 Second
above 40 RPM
Max Measurement Rate
Up to 100 times per second (Standard Gate) or up to 1000 (Fast Gate)
Dependent on input frequency. Input must be > measurement rate
Scale Mode
Scaling Computation
Programmable scaling 0.0001 to 99,999
Front panel push button programmable
Decimal Point
User Selectable (0-3 decimal places max)
Front panel push button programmable
Memory
Maximum and minimum recall from front panel push buttons
Dimensions
1/8 DIN by 3.94‖ [100 mm] deep
Panel cut out: 1.74‖ H x 3/58‖ W [44 mm x 91 mm]
Input Power
Standard 100 - 240 Vac (50/60 Hz) 8VA
Or Optional 12 Vdc or 24Vdc isolated 6W
Recommended Sensors
Optical – ROS-W
Infrared – IRS-W
Optical – ROS-HT-W-25
Laser – ROLS-W
Optical – ROSM-5W
Laser – SLS-115/230
Proximity – P5-11
Mag/Amp – MT-190W
Magnetic – M-190W
Gas Engine - GE-200
Sensor Power Output
12Vdc @ 60mA standard, or optional 5Vdc @ 60mA or 24Vdc @ 30mA to sensor
Pulse Repeater Output
TTL
0 to 5 V TTL compatible, one pulse out for each pulse in
Menu selectable polarity
Serial Interface
Bi-directional RS232C, USB or Ethernet Interface
Analog Output
Voltage
(AO)
: 0 to 5 Vdc, 5 mA max load, Isolated or Non-isolated
OR
Current Source
(IO)
: 4 to 20 mA (500
max load with internal 12V Compliance Voltage),
Isolated or Non-isolated. (1-5V with 250
load resistor)
15 bit resolution. Front panel push button programmable for full scale and offset RPM ranges.
Alarm Capability
Two alarm set points: High or Low Alarm Limits
Latching or Non-latching
Front panel push button or remotely programmable
Hysteresis and low limit lockout are programmable
Relays can be set as fail safe.
Alarm Outputs
Form C relay contacts, rated 1A at 115 Vac or 230 Vac
Alarm Reset
Automatic or manual reset. Front panel push button programmable
Remote reset via AUXiliary input.
Remote Programming
Unit can be remotely programmed using optional Serial Interface.