background image

Page 16

 

 
 

APPENDIX A - SCALING THE ACT FOR ENGINEERING DISPLAYS 

The 

SCALE  Mode

  must  be  used  to  display  RPM  in  applications  where  there  is  more  than  one  pulse  per  revolution.    Below 

describes how to use this mode and other applications that need to be scaled. 

When using the scaling function of the ACT Tachometer it is possible to multiply the input signal by any value from 0.0001 to 
99,999 making it possible to display the actual output in virtually any format. 

The  most  important  thing  to  note  is  that  the  instrument  takes  all  tachometer  measurements  in 

pulses  per  second

.    The 

RPM

 

Mode

 requires a 1 pulse per revolution input, so it simply uses a built in scale factor of 60.  

Input 

Conversions (Scale Factor) 

Scales Display To 

Pulses 

 1 Rev   

60 Seconds 

 Revs  

———     x  ———     x  —————     =  ——— 
Second 

1 Pulse 

   Minute 

Minute 

In an application with multiple pulses per rev: 

Input 

Conversions (Scale Factor) 

Scales Display To 

Pulses 

 1 Rev 

60 Seconds 

 Revs  

———      x  ————  x  —————     =  ——— 
Second 

N pulses 

   Minute 

Minute 

Therefore, to read out in RPM, the scale factor is 60 ÷ 

N

, where 

N

 is the number of pulses. 

Thus,  if  the  system  gave  out 4 pulses  per  revolution, the  scale  factor  becomes  60  ÷ 4  = 15.    The trivial  case  is  the  60  toothed 
gearwheel used in older systems which gave out 60 pulses per revolution, reducing the scale factor to 1, or measuring frequency 
(cycles per second) directly. 

All  that  is  required  to  scale  the  unit  is  a  bit  of  common  sense,  a  basic  knowledge  of  mathematics  (you  can  of  course  use  a 
calculator) and some relationships pertaining to your application (e.g. 1 yard = 36 inches, or 1 yard = 0.914402 meters).  Refer to 

Appendix B

 

for some useful conversions. 

A  very useful  formula  for this application is knowing the circumference of the  shaft  you are  monitoring.  This could also be a 
speed wheel, tire etc.  The circumference = π x diameter (π = 3.14159). 

In  order  to  scale  we  need  to  know  what  we  want  as  opposed  to  what  we  have,  and  some  relationship  between  the  two.    For 
example: 

1) 

Suppose we have a wheel turning on a roll of paper measuring its linear speed.  The wheel has a diameter of d inches.  Each 
time the wheel turns one complete revolution, π x d inches (the circumference) of paper moves under the wheel and we get 
one pulse into the tachometer.  We want to know at what speed we are producing paper in yards per minute. 

The input is measured in pulses per second.  There is one pulse per revolution, so: 

Input 

 

Conversions (Scale Factor) 

 

Scales Display To 

Pulses 

 1 Rev 

π x d Inches 

   Yard 

60 Seconds 

 Yards  

———   x  ———   x  —————   x  ————   x  —————  =  ———— 
Second 

 Pulse 

      Rev 

36 Inches 

   Minute 

Minute 

Scale Factor Of 

Comment 

Gives Read Outs In

 

(π x d‖) 

circumference of wheel 

inches per second 

(π x d‖) ÷ 36 

36 inches in a yard 

yards per second 

((π x d‖) ÷ 36) x 60 

60 seconds in a minute 

yards per minute 

5.2360 x d‖ 

multiplying the known 

yards per minute 

Say the diameter (d) is 10 inches.  We get that pulses per second = 52.36 yards per minute and our scale factor is thus 52.36 for a 
10 inch diameter shaft. 

2) 

Suppose we have a shaft turning on a conveyor and we know that for each turn of the shaft, the conveyor moves X inches 
and we get one pulse into the tachometer.  This step eliminates having to calculate the circumference.  If we wanted to know 
speed in meters per second then review the following. 

The Input is measured in pulses per second.  There are X inches per pulse, so: 

Scale Factor of 

Comment 

Scales Display To 

inches per pulse 

inches per second 

X x 0.914402 ÷ 36 

1 yard = 0.914402 meters 

meters per second 

 

36 inches in a yard 

X x 0.0254 

multiply out 

meters per second 

The scale factor is thus 0.0254 x X (where X is in inches). 

Содержание ACT-3X

Страница 1: ...Totalizer Ratemeter User Manual and Reference Guide MONARCH INSTRUMENT 15 Columbia Drive Amherst NH 03031 USA Phone 603 883 3390 Fax 603 886 3300 E mail support monarchinstrument com Website www mona...

Страница 2: ...e personal injury or death may occur as a result 7 This instrument may not be safe for use in certain hazardous environments and serious personal injury or death could occur as a result of improper us...

Страница 3: ...4 3 2 3 UP and DOWN BUTTONS 5 3 2 4 RECALL BUTTON 5 4 0 OPERATION 5 4 1 Modes of Operation Channel 1 5 4 1 1 RPM Mode 5 4 1 2 Frequency Mode 5 4 1 3 Scale Mode Ratemeter 5 4 1 4 Single Event Capture S...

Страница 4: ...5 9 11 5 10 11 5 11 12 5 12 12 6 0 SERIAL OUTPUT 12 6 1 Data from the Serial Interface 12 6 2 Serial Commands 12 6 2 1 Run Mode Commands 12 6 2 2 Control Commands 13 7 0 SPECIFICATIONS 14 8 0 OPTIONS...

Страница 5: ...xed equipment or permanently connected If permanently connected disconnection from the supply must be possible via a customer supplied switch or circuit breaker rated at 120V or 240V dependent on loca...

Страница 6: ...ve Hot wire to the terminal marked L and the Neutral Return wire to the terminal marked N NOTE The ground connection is not required as the unit is fully isolated from the mains If the unit is dc powe...

Страница 7: ...nput is also referred to as Channel 2 CH 2 and will accept a TTL input or any signal up to 12Vdc It has a weak pull up internally and can be used with a set of potential free contacts The AUX input is...

Страница 8: ...is another input pulse It is more useful at slow speeds as it appears to be on continuously at higher inputs It gives an indication that a valid input trigger signal is present 3 1 3 MAX and MIN LEDS...

Страница 9: ...1 2 Frequency Mode In the Frequency Mode the unit displays input pulses per second or more commonly Hertz Hz This is the most basic mode of operation The range of measurement in this mode is 0 0833 t...

Страница 10: ...nding on the sense programmed It acts as a gate preventing the input signal from updating the unit 4 2 3 Single Event Capture When programmed as Single Event Capture this input acts as the second inpu...

Страница 11: ...become de energized Thus in the event of a power failure the relays will drop out by default creating the equivalent of an alarm condition 4 5 Analog AO and Current IO Output The ACT 3X has options f...

Страница 12: ...or 14 640 RPM the internal update rate is the period of the input frequency Thus the response of the alarms etc can be seen to be a function of the input Above an input of 244 Hz the alarms respond wi...

Страница 13: ...d scale factor Press RECALL to exit up one level without making a change or press SET to save the change The edit buttons function as follows RESET changes the digit being edited blinking digit UP inc...

Страница 14: ...EGative or POSitive Press the SET button to select the new setting or the RECALL button to exit without saving the settings 5 3 Sets the decimal point on the displayed reading To enter this menu item...

Страница 15: ...a change or press SET to save the change 5 6 2 FULL SCALE Sets the Full Scale value for the Analog output Press the SET button and use the buttons to edit the value as per above Press RECALL to exit u...

Страница 16: ...ent occurs Other information is sent on demand and is covered in the following section The messages are sent as standard ASCII and all messages end with a carriage return CR There is no Line feed sent...

Страница 17: ...mand Category Argument Value eg CH_1 TYPE SCALE 60 0 sets the Scale Mode Scale factor to 60 0 Command Argument eg DECPT NONE sets the Decimal Point to none Command Category Argument Action CH_1 Channe...

Страница 18: ...100 times per second Standard Gate or up to 1000 Fast Gate Dependent on input frequency Input must be measurement rate Scale Mode Scaling Computation Programmable scaling 0 0001 to 99 999 Front panel...

Страница 19: ...preadsheet Software available for download at www monarchinstrument com ROLS W Remote Optical Laser Sensor with 8 foot cable ROS W Remote Optical Sensor with 8 foot cable ROS P 25 Remote Optical Senso...

Страница 20: ...ing the circumference of the shaft you are monitoring This could also be a speed wheel tire etc The circumference x diameter 3 14159 In order to scale we need to know what we want as opposed to what w...

Страница 21: ...il the display shows and then press the SET button The display will show the current scale factor value with the right most digit flashing The UP and DOWN buttons change the flashing digit The RESET b...

Страница 22: ...an error in the placement of the sensors The tape edges won t be exactly 1 inch apart Assuming the edges were really 1 01 inches apart there would be 1 error So at 130 MPH your reading would be 128 7...

Страница 23: ...hat the device is set up for DHCP by default so it will get an IP address from your local server Once the search is complete the window will be populated as shown next The current device setting is sh...

Страница 24: ...ons to set the required value Press RECALL to exit up one level without making a change or press SET to make the change The edit buttons function as follows RESET changes the digit being edited blinki...