5.21.4 Inlet Extension Installation
1. Place the inlet extension on the manifold.
2.
Install mounting screws through the nozzle flange and into the manifold.
3. Torque screws to manifold using anti-seize compound on threads.
4. Place a zone number on each wire and thermocouple.
5. Tape wires for each zone together.
6. Install the wires into the wire channels and secure with wire retainers.
Feed the wires back through the wire channel in the mold base to the
electrical box.
1
7
6
2
5
3
4
8
1. Screw
2. Center heater
3. Back plate
4. Manifold
5. Ground wire
6. Thermocouple
7. Cover plate
8. Set screw
Figure 5-41 3-piece assembly
5-48
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.
ASSEMBLY
Hot Runner User Manual