5.5 Hot Valve / Hot Sprue / F Type
CAUTION
Ensure the thermocouple is not damaged during machining.
CAUTION
Hot valve and hot sprue gated systems are supplied with gate seals that are
oversize in length. They must be machined prior to installing the nozzle into
the nozzle well bore.
NOTE
A hot sprue also requires completion of the gate detail. Refer to the nozzle
well detail drawing.
Heat expansion of the nozzle must be taken into consideration.
Check the chart on the General Assembly drawings for the length and
contact height required. See contact length “H” on table below.
Always refer to the General Assembly drawing to confirm the contact
length.
Table 5-1 Typical Contact Length
Polymer Structure
Contact Length “H” in mm (in.)
Amorphous Filled or Reinforced
4.00 (0.16)
Semi-crystalline Filled or Reinforced 3.00 (0.12)
Crystalline Filled or Reinforced
2.00 (0.08)
Figure 5-4 Hot valve / hot sprue gated system
5-4
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.
ASSEMBLY
Hot Runner User Manual