16.2 TIT Edge Gate Seals
The following procedure applies to TIT Edge nozzles only. The gate seals
have an M6 thread.
16.2.1 Remove the Gate Seal
NOTE
If the cavity plate is easily removed you can access the nozzle seals while
still in the system. Hot Runner systems must be cold before the cavity plate
can be removed.
1. Apply penetrating oil to the threads.
2. Heat the nozzle to processing temperature to melt any residual plastic
that may be in the gate seal area.
3. When the nozzle approaches set temperature, use
Mold-Masters
supplied
socket to remove the seal.
NOTE
Cylindrically ground gate seals cannot be reinstalled.
16-2
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.