10.10.2 Hydraulic Limit Switch Option (6500 Series and
6600 Series)
Refer to “Test the Proximity Sensor for Hydraulic Limit Switch Option” on
page 10-20.
1. Lubricate the sides of the actuator cylinder before installing into the
hydraulic plate.
2. Make sure that there are no sharp edges on the hydraulic plate.
3. Tap the cylinder into the bore of the actuator plate with a nylon mallet.
4. Position the piston installation tool (PS0003TOOL01) on top of the
cylinder.
5. Install the valve pin and piston into the cylinder bottom.
6.
Press the valve pin into position, using a nylon mallet to finish seating the
valve pin into the assembly.
7. Remove the installation tool.
8. Check that the cylinder top dowel and O-rings are installed.
9. Install the hydraulic O-ring into the cylinder top.
Hydraulic O-ring
10. Install the cylinder top. The piston top will protrude from the cylinder top.
11. Install the trigger ring on the head of piston top and lock its position with a
flat head screw. Thread locking is recommended. (LOCTITE-243)
Limit switch cylinder top O-ring
10-17
HYDRAULIC / PNEUMATIC ACTUATORS
Hot Runner User Manual
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.