5.15 Manifold Thermocouple Installation
This procedure only applies to integrated systems.
1. Although not necessary, a thermal compound may be applied to the
thermocouple tip to ensure a good contact.
2. Clean the thermocouple bore. Suggestion for 1.5 mm (0.06 in.)
thermocouples is to use a 1/16 inch drill in a pin vise.
3. Insert the thermocouple into the bore. Check that the thermocouple is
touching the bottom of the hole.
4. Press down on the thermocouple and gently bend the thermocouple
sheath through 90°.
5. Check that the thermocouple sits in the manifold cutout.
6. Install the thermocouple washer and screw.
7. Install a zone number on each wire and thermocouple.
8. Tape wires for each zone together.
9. Install the wires into wire channels and secure with wire retainers.
10. Feed the wires back through the wire channel in the mold base to the
electrical box.
4
1. Thermocouple
2. Screw
3. Washer
4. Assembly
1
2 3
90°
Figure 5-22 Thermocouple installation
5-33