18.8 Melt-Disk System Startup
CAUTION
Ensure that the correct startup procedure for your system is used.
For systems with a standard Melt Link, see:
“18.8.1 Startup - Melt Link” on page 18-11.
For systems with a Reverse Melt Link, see:
“18.8.2 Startup - Reverse Melt Link ONLY” on page 18-12.
Failure to follow the correct procedure could result in damage occurring in
the Hot Runner.
CAUTION
See also “Section 8 - System Startup and Shutdown” and your controller user
manual.
18.8.1 Startup - Melt Link
WARNING
When the mold is open never inject material through Hot Runner system
under high pressure. Failure to do so can result in serious injury or death.
CAUTION
Failure to follow this procedure may result in leakage or damage occurring
in the Hot Runner.
CAUTION
IMPORTANT
When running thermally sensitive materials, use a thermally stable material
as recommended by the material supplier for the initial startup.
1. Turn on the machine barrel and mold cooling system.
2. Prior to start up, ensure the:
a) Machine barrel is up to processing temperature.
b) Mold cooling is on and at cooling temperature.
3. Heat manifold zones and inlets to processing temperature.
4. Heat Melt-Disks to processing temperature.
IMPORTANT
Set Melt-Disk temperature at least 6°C (10°F) lower than nozzles.
5. Heat nozzles to processing temperature.
A small amount of material may weep at this stage.
6. Heat soak for a minimum of 10 minutes.
7. Fill the system under low pressure extrude using screw rotation.
18-11
MELT-DISK SYSTEM
Hot Runner User Manual
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.