16. Check the machine is in Mold Set mode.
17. Open the mold moving the cavity plate away from the manifold plate.
1. Stationary platen
2. Cavity plate
3. Moving platen
4. Core plate
1
2
3
4
Figure 15-12 Latch cavity plate to core plate
18. Apply lockout / tagout. Refer to the controller and machine manufacturer’s
documentation for procedures.
Latch the Cavity Plate to the Core Half - continued
15.13 Latch the Cavity Plate to the Manifold Plate
(Hot Half)
WARNING
Make sure the machine has been locked out and tagged out in accordance
to the machine’s documented procedures. Failure to do so could lead to
serious injury or death.
CAUTION
The nozzles must be within 55°C (130°F) of mold temperature to prevent
damage to Hot Runner and mold components. For cylindrical valve gated
systems, valve pins should be in the open position prior to removal of the
cavity plate to prevent damage.
CAUTION
1. Check the machine is locked out / tagged out.
2. Lubricate the guide pins on the Hot Half.
3. Remove lockout / tagout.
4. Check the machine is in Mold Set mode.
5. Slowly close the mold.
6. Check the machine has been locked out / tagged out. Refer to the
controller and machine manufacturer’s documentation for procedures.
7. Remove the latches on both sides of the mold.
8. Latch the cavity plate to manifold plate or manifold backing plate.
9. Remove lockout / tagout.
15-22
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.
MAINTENANCE