8
3
Operation
Revision 3
©
Moffat Ltd, September 2009
E32SUBC OVEN and PROOFER
Service Settings (refer 3.3.5 / 3.3.6 / 3.3.7)
Temperature Offset
Setting range
Default Setting
Temp offset oven probe
+/-11
-1
Temp offset prover air probe
+/-11
+4
Temp offset prover water probe
+/-11
+2
Diagnostic
Oven probe temp
displays current probe reading
Proofer probe air temp
displays current probe reading
Proofer probe water temp
displays current probe reading
Door
switch
Open/Close
displays door switch status
Float switch Open/Close
displays water tank float switch status
Humidity probe reading
displays current probe humidity reading
Oven heat relay output status
displays ON or OFF status
Oven power ON relay output status
displays ON or OFF status
Proofer heat relay output status
displays ON or OFF status
Proofer water heater relay output status displays ON or OFF status
Proofer power ON relay output status
displays ON or OFF status
Oven fan relay output status
displays ON or OFF status
Counters
Relay cycles - oven heater
Relay cycles - proofer air heater
Relay cycles - proofer water heater
Error counter - oven probe
Error counter - oven hi temp
Error counter - proofer air probe
Error counter - proofer air hi temp
Error counter - humidity sensor
Error counter - proofer water probe
Error counter - proofer water hi temp
Error counter - proofer water low
Содержание turbofan E32SUBC
Страница 1: ...Moffat Ltd September 2009 Revision 3 E32SUBC OVEN and PROOFER E32SUBC Oven and Proofer Service Manual...
Страница 4: ...Moffat Ltd September 2009 Revision 3 E32SUBC OVEN and PROOFER...
Страница 49: ...45 7 Accessories Revision 3 Moffat Ltd September 2009 E32SUBC OVEN and PROOFER...
Страница 68: ...Moffat Ltd September 2009 Revision 3 E32SUBC OVEN and PROOFER...