3.3.6
Service Diagnostic (con’t)
The following Service Settings are adjustable by the Authorised Service Agents:-
Use the ‘Up’ / ‘Down’ scroll keys to scroll through the service menu
The reading for the Proofer Humidity screen will display
The following menu options allow for the switching of the 24Vdc output relays. The
output can be turned on by holding the right side temp key down, it will turn off when
key is released.
The Oven Heater Relay Output screen will display.
Turning on operates only the 24Vdc relay and
not
the element contactor
The Oven Power Relay Output screen will display.
Turning on operates the 24Vdc relay and turns on the lights.
The Proofer Air Heater Relay Output screen will display.
Turning on operates only the 24Vdc relay and
not
the element.
The Proofer Water Heater Relay Output screen will display.
Turning on operates only the 24Vdc relay and
not
the element.
The Proofer Water Heater Relay Output screen will display.
Turning on operates the 24Vdc relay and turns on the lights and fan.
The Oven Fan Relay Output screen will display.
Turning on operates the 24Vdc relay and
not
the fan.
The next screen tests the pixels in the display and LED’s on the Control Panel.
Содержание turbofan E32SUBC
Страница 1: ...Moffat Ltd September 2009 Revision 3 E32SUBC OVEN and PROOFER E32SUBC Oven and Proofer Service Manual...
Страница 4: ...Moffat Ltd September 2009 Revision 3 E32SUBC OVEN and PROOFER...
Страница 49: ...45 7 Accessories Revision 3 Moffat Ltd September 2009 E32SUBC OVEN and PROOFER...
Страница 68: ...Moffat Ltd September 2009 Revision 3 E32SUBC OVEN and PROOFER...