6
Service Procedures
34
Revision 3
©
Moffat Ltd, September 2009
E32SUBC OVEN and PROOFER
Figure 6.2.4b
Thermostat probe
Two screws
Figure 6.2.4a
1) Remove R/H service panel (refer 6.1.2).
2) Cut cable ties securing thermostat probe
wires.
3) Undo the 2 screws on the flange which holds
the thermostat probe where the probe enters
the oven (inside oven).
4) Unplug probe from connector
5) Remove probe by drawing probe ,bracket and
wires out of oven.
6) Install the new probe in the reverse order.
Use high temperature (232°C / 450°F mini-
mum) RTV silicone sealant to seal probe hole
in oven liner.
6.2.4 Temperature
probe
Figure 6.2.5
6.2.5 Heating
contactor
1) Remove the right hand service panel (refer
6.1.2).
2) Unclip contactor from the gear plate.
Contactor
3) Clip new contactor onto gear plate.
4) Transfer wires from old contactor to new con-
tactor, ensuring all wires are in their correct
positions.