21
5
Trouble-shooting
Revision 3
©
Moffat Ltd, September 2009
E32SUBC OVEN and PROOFER
ALL INSTALLATION AND SERVICE REPAIR WORK MUST BE CARRIED OUT BY
QUALIFIED PERSONS ONLY.
WARNING:
5.1
Error Messages
Oven
Door open
Door open, Microswitch faulty
Probe open error
Oven temperature probe open circuit
Probe short error
Oven temperature probe short circuit
Hi temp error
Oven tempe 25
o
C
Proofer
Air probe open error
Proofer air temperature open circuit
Air probe short error
Proofer air temperatures short circuit
Air Hi Temp error
Proofer tempe 25
o
C
Water probe open error
Proofer water temperature probe open circuit
Water probe short error
Proofer water temperature probe short circuit
Water Hi Temp error
Water tank over tempe 25
o
C
Water low error
Proofer water level low for more than 30 secs
Humidity short error
Short in probe or between blue/yellow wires
Humidity open error
Open circuit in humidity probe or
Short between white/yellow wires
Blue or Yellow wires disconnected
97% Actual humidity reading
White wire disconnected.
Unit shuts down will not start
Short circuit between Blue/ White wire to humidity probe
Blown controller fuse.