UNIFLOW
®
2 PULSED THERMODE CONTROL
990-228
A-1
APPENDIX A
TECHNICAL SPECIFICATIONS
Electrical Mains
AC Voltage Ranges:
Model 1-292-01 ..................................................................................................... 90 to 132 VAC
Models 1-292-01-01 & 1-292-01-02 .................................................................... 180 to 264 VAC
Line Frequency
.................................................................................................................50 or 60 Hz
Line Phase
.................................................................................................................................. Single
Input Circuit Breaker Rating
.....................................................................................................15 A
Power Cord Connection
.....................................................European CE Harmonized Wiring Code,
or NEMA Wiring Code
Environment
Location
..............................................................................................................................Indoor Use
Ambient Temperature:
Maximum
.................................................................................................................104
q
F (40
q
C)
Minimum
....................................................................................................................59
q
F (15
q
C)
Relative Humidity, Maximum
..........................................................................93% at 104
q
F (40
q
C)
Dimensions
Height
x
Width
x
Depth ......................... 12.5 in. (317 mm) 10 in. (254 mm) 20.75 in. (527 mm)
Weight:
4 KVA Models .................................................................................................... 58 lbs (26.31 kg)
2 KVA Models .................................................................................................... 46 lbs (20.86 kg)
Performance
User Programmable Heat Profiles
..................................................................................................15
Flash Memory
Thermocouple Inputs (automatic recognition):
Type E .......................................................................................... For temperatures below 900
q
C
Type J ........................................................................................... For temperatures below 750
q
C
Type K ......................................................................................... For temperatures below 1000
q
C
Thermocouple Calibration Input Standards
..................................... User provided NIST standard
(separate calibration required for each thermocouple type)
Содержание 1-292-01
Страница 19: ......
Страница 27: ......
Страница 43: ......
Страница 53: ......
Страница 55: ......
Страница 59: ......
Страница 72: ...APPENDIX B ELECTRICAL AND DATA CONNECTIONS UNIFLOW 2 PULSED THERMODE CONTROL 990 228 B 13 Relay State Timing ...
Страница 77: ......
Страница 79: ......
Страница 95: ......
Страница 107: ......