APPENDIX D: COMMUNICATION CODES
UNIFLOW
®
2 PULSED THERMODE CONTROL
990-228
D-11
10 = REFLOW_BELOWPREHEAT
11 = ACCESSDENIED
12 = SETDEFAULTS
13 = FIRINGSWOPEN
14 = SAFETYTIMER
15 = FIRINGSWNOTACTIVATED
16 = DECREASEHEATINGRATE
17 = INCREASEHEATINGRATE
18 = REPLACE
19 = CLEAN
20 = REPLACERESET
21 = CLEANRESET
22 = POWERMODE
23 = NOHEATSWITCH
24 = PREHEATON
25 = AUTOSCALE
26 = HEADDOWN
27 = PREHEATTIME
28 = RISETIME
29 = HEATTIME
30 = COOLTIME
31 = MODIFYPROFILE
32 = LASTPROFILE
33 = IDEALPROFILE
34 = EMERSTOP
35 = MAXTEMP
36 = NOPWR
37 = OVPWR
38 = THERMODE
39 = ACCESSDENIEDREM
40 = FOOTSWOPEN
6
Bytes
Total
PROFILE
“DR” Read
ProfileNum (Profile number read: 01 - 15)
2 Bytes
,
1
Byte
PreheatTemp (Preheat temperature: 060 - 999)
3 Bytes
,
1
Byte
ReflowTemp (Reflow temperature: 060 - 999)
3 Bytes
,
1
Byte
CoolTemp (Cool temperature: 060 - 999)
3 Bytes
,
1
Byte
PreheatTime (Preheat time: 000 – 999)
3 Bytes
,
1
Byte
RiseTime (Rise time: 00 – 99)
2 Bytes
,
1
Byte
ReflowTime (Reflow time: 000 – 999)
3 Bytes
,
1
Byte
CoarseRate (Coarse heating rate: 0 – 3)
1 Byte
0 = Very Slow
1 = Slow
2 = Medium
3 = Fast
27 Bytes Total
Содержание 1-292-01
Страница 19: ......
Страница 27: ......
Страница 43: ......
Страница 53: ......
Страница 55: ......
Страница 59: ......
Страница 72: ...APPENDIX B ELECTRICAL AND DATA CONNECTIONS UNIFLOW 2 PULSED THERMODE CONTROL 990 228 B 13 Relay State Timing ...
Страница 77: ......
Страница 79: ......
Страница 95: ......
Страница 107: ......