APPENDIX A: TECHNICAL SPECIFICATIONS
UNIFLOW
®
2 PULSED THERMODE CONTROL
A-2
990-228
Temperature Control
Accuracy:
600
q
C and below ..................................................
r
6
q
C or
r
2% of reading, whichever is greater
Above
600
q
C ..........................................................................................................
r
3% of reading
Repeatability
................................................................................................................
r
1% of setting
Display
Range
................................................................................................................ 15
q
C to 999
q
C
Settings:
Preheat ........................................................................................................................60
q
to 300
q
C
Reflow
(default)..........................................................................................................60
q
to 600
q
C
Reflow (extended mode operation) ............................................................................60
q
to 999
q
C
Periods:
Preheat .................................................................................................................0
to
99.9 seconds
Rise …………………………………………………………………………….0.0 to 9.9 seconds
Reflow ..............................................................................................................0.1
to
99.9 seconds
Heating Rate Control
Coarse ..........................................................................................Fast, Medium, Slow, Very Slow
Switched Input Electrical Requirements
Form and Rating
............................. Switch or sensor inputs must be normally open SPST switches,
transistors or opto-isolators rated at 24 VDC, 20 MA minimum
Heat Profile Select
................................................................Select 15 heat profiles using four inputs
activated in a binary coded pattern
Operator Initiation Switch
.................................................................... 1-level or 2-level foot switch
Heat Initiation Sensor
..................................................... Heat force or Uniflow 2 head down sensor
for initiating thermode heating
No Heat Switch
.......................................................................................................... Heat only inhibit
Emergency Stop (CE Requirement)
..................................................... SPST switch open to remove
valve driver power and retract head
Analog Inputs
Thermocouple
............................................................................................................... E, J, or K type
Thermocouple Extension Cables, Omega Standard:
Type E, Unitek PN 10-355-01.............................................................................60 in. (152.4 cm)
Type J, Unitek PN 10-355-01-01 ........................................................................60 in. (152.4 cm)
Type K, Unitek PN 10-355-01-02 .......................................................................60 in. (152.4 cm)
Содержание 1-292-01
Страница 19: ......
Страница 27: ......
Страница 43: ......
Страница 53: ......
Страница 55: ......
Страница 59: ......
Страница 72: ...APPENDIX B ELECTRICAL AND DATA CONNECTIONS UNIFLOW 2 PULSED THERMODE CONTROL 990 228 B 13 Relay State Timing ...
Страница 77: ......
Страница 79: ......
Страница 95: ......
Страница 107: ......