CHAPTER 3: USING UNIFLOW
®
2 PROGRAMMING FUNCTIONS
UNIFLOW
®
2 PULSED THERMODE CONTROL
990-228
3-5
Replace Counter
Press the
4
key to edit the replace counter. The count that you enter will raise an alarm to signal the
operator that it is time to replace the thermode. Thermodes ultimately fail due to repeated heat cycles
that cause internal cracking, slowing down heat generation in the thermode. In addition, repeated
heating cycles cause the thermocouple junction to oxidize and, eventually, break free of the thermode.
DATA EDIT Keys
The data edit keys allow you to edit the time and temperature
parameters of the heat profile on the graphic display. The
PREHEAT
,
RISE
,
REFLOW
and
COOL
keys are vertically aligned
with the profile heating states as displayed on the graphic
screen.
The keys are
only
active when the graphic screen is displayed.
Example:
To change the temperature of the
Reflow period for Heating Profile 1 to 500
q
C:
1.
Press the
GRAPH
key to display the
graphic screen.
2.
Press the data edit
REFLOW [
q
C]
key.
The
Reflow
temperature value of 350
40
q
C
1
Last
Profile
150
…
350 180
Celsius
01.0
1.0
03.0 … Seconds
will now be highlighted.
3.
Enter
500
with the keypad.
4.
Press the
GRAPH
key to store the new
Reflow
temperature value to
Heating
Profile 1
. The graph will now display
500
as shown on the right.
40
q
C
1
Last
Profile
150
…
500
180 Celsius
01.0
1.0
03.0
… Seconds
Saving Changed Values
When you change values, they are saved in the Control’s flash memory (“flash” for short) when the
GRAPH
,
DATA
,
COUNTERS
,
HEATING RATE
, or
SETUP
screens are used.
CAUTION:
Before
you power down, go to one or more of the screens above and verify your changes.
If you do
not
use one of these screens before powering down, your changes will
not
be saved.
NOTE:
While data is being saved to flash, the screen will display
***** SAVING CHANGES *****
Содержание 1-292-01
Страница 19: ......
Страница 27: ......
Страница 43: ......
Страница 53: ......
Страница 55: ......
Страница 59: ......
Страница 72: ...APPENDIX B ELECTRICAL AND DATA CONNECTIONS UNIFLOW 2 PULSED THERMODE CONTROL 990 228 B 13 Relay State Timing ...
Страница 77: ......
Страница 79: ......
Страница 95: ......
Страница 107: ......