11. OPTIONS AND AUXILIARY EQUIPMENT
11 - 60
11.10 Molded-case circuit breakers, fuses, magnetic contactors (recommended)
(1) For main circuit power supply
Always use one molded-case circuit breaker and one magnetic contactor with one servo amplifier. When
using a fuse instead of the molded-case circuit breaker, use the one having the specifications given in
this section.
Molded-case circuit breaker (Note 1)
Fuse
Frame, rated current
Servo amplifier
Power factor
improving reactor is
not used
Power factor
improving reactor is
used
Voltage AC
[V]
Class Current
[A]
Voltage AC
[V]
Magnetic
contactor
(Note 2)
MR-J4-10A(-RJ)
30 A frame 5 A
30 A frame 5 A
MR-J4-20A(-RJ)
30 A frame 5 A
30 A frame 5 A
10
MR-J4-40A(-RJ)
30 A frame 10 A
30 A frame 5 A
15
MR-J4-60A(-RJ)
30 A frame 15 A
30 A frame 10 A
MR-J4-70A(-RJ)
30 A frame 15 A
30 A frame 10 A
MR-J4-100A(-RJ) 30 A frame 15 A
30 A frame 10 A
20
S-N10
S-T10
MR-J4-200A(-RJ) 30 A frame 20 A
30 A frame 20 A
40
S-N20
(Note 3)
S-T21
MR-J4-350A(-RJ) 30 A frame 30 A
30 A frame 30 A
70
S-N20
S-T21
MR-J4-500A(-RJ) 50 A frame 50 A
50 A frame 50 A
125
S-N35
MR-J4-700A(-RJ) 100 A frame 75 A
60 A frame 60 A
150
MR-J4-11KA(-RJ) 100 A frame 100 A
100 A frame 100 A
200
S-N50
MR-J4-15KA(-RJ) 125 A frame 125 A
125 A frame 125 A
250
S-N65
MR-J4-22KA(-RJ) 225 A frame 175 A
225 A frame 175 A
240 T
350
300
S-N95
MR-J4-60A4(-RJ) 30 A frame 5 A
30 A frame 5 A
10
MR-J4-100A4(-RJ) 30 A frame 10 A
30 A frame 5 A
15
MR-J4-200A4(-RJ) 30 A frame 15 A
30 A frame 10 A
25
S-N10
S-T10
MR-J4-350A4(-RJ) 30 A frame 20 A
30 A frame 15 A
35
MR-J4-500A4(-RJ) 30 A frame 20 A
30 A frame 20 A
50
S-N20
(Note 3)
S-T21
MR-J4-700A4(-RJ) 30 A frame 30 A
30 A frame 30 A
65
S-N20
S-T21
MR-J4-11KA4(-RJ) 50 A frame 50 A
50 A frame 50 A
100
S-N25
MR-J4-15KA4(-RJ) 60 A frame 60 A
60 A frame 60 A
150
S-N35
MR-J4-22KA4(-RJ) 100 A frame 100 A
100 A frame 100 A
480 T
175
600
S-N50
Note 1. When having the servo amplifier comply with the IEC/EN/UL/CSA standard, refer to appendix 4.
2. Use a magnetic contactor with an operation delay time (interval between current being applied to the coil until closure of
contacts) of 80 ms or less.
3. S-N18 can be used when auxiliary contact is not required.
Содержание MR-J4-100A
Страница 9: ...A 8 MEMO ...
Страница 61: ...1 FUNCTIONS AND CONFIGURATION 1 44 MEMO ...
Страница 67: ...2 INSTALLATION 2 6 MEMO ...
Страница 137: ...3 SIGNALS AND WIRING 3 70 MEMO ...
Страница 261: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Страница 291: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 30 MEMO ...
Страница 299: ...8 TROUBLESHOOTING 8 8 MEMO ...
Страница 319: ...9 OUTLINE DRAWINGS 9 20 MEMO ...
Страница 461: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 36 MEMO ...
Страница 511: ...14 COMMUNICATION FUNCTION 14 38 MEMO ...
Страница 559: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Страница 583: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Страница 621: ...APPENDIX App 38 ...
Страница 639: ......