5. PARAMETERS
5 - 43
Control
mode
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
P S T
PC37
VCO
Analog speed
command
offset/
Analog speed
limit offset
Set the offset voltage of VC (Analog speed command).
For example, if CCW rotation or positive direction travel is provided by switching on
ST1 (Forward rotation start) while applying 0 V to VC, set a negative value.
When automatic VC offset is used, the automatically offset value is set to this
parameter. (Refer to section 4.5.4.)
The initial value is provided before shipment by the automatic VC offset function on
condition that the voltage between VC and LG is 0 V.
Setting range: -9999 to 9999
The value
differs
depending
on the
servo
amplifiers.
[mV]
Set the offset voltage of VLA (Analog speed limit).
For example, if CCW rotation or positive direction travel is provided by switching on
RS1 (Forward rotation selection) while applying 0 V to VLA, set a negative value.
When automatic VC offset is used, the automatically offset value is set to this
parameter. (Refer to section 4.5.4.)
The initial value is provided before shipment by the automatic VC offset function on
condition that the voltage between VLA and LG is 0 V.
Setting range: -9999 to 9999
Set the offset voltage of TC (Analog torque command).
Setting range: -9999 to 9999
PC38
TPO
Analog torque
command
offset/
Analog torque
limit offset
Set the offset voltage of TLA (Analog torque limit).
Setting range: -9999 to 9999
0
[mV]
PC39
MO1
Analog
monitor 1
offset
Set the offset voltage of MO1 (Analog monitor 1).
Setting range: -9999 to 9999
0
[mV]
PC40
MO2
Analog
monitor 2
offset
Set the offset voltage of MO2 (Analog monitor 2).
Setting range: -9999 to 9999
0
[mV]
PC43
ERZ
Error
excessive
alarm level
Set an error excessive alarm level.
You can change the setting unit with "Error excessive alarm level" in [Pr. PC24].
Set this per revolution for rotary servo motors and direct drive motors. Set this per
mm for linear servo motors.
Setting "0" will be "3 rev" for rotary servo motors and direct drive motors and "100
mm" for linear servo motors. A setting over 200 rev will be clamped at 200 rev.
Setting range: 0 to 1000
0
[rev]/
[mm]
_ _ _ x For manufacturer setting
0h
_ _ x _
0h
_ x _ _
0h
PC44
*COP9
Function
selection C-9
x _ _ _ Load-side encoder cable communication method selection
Select the communication method of the encoder cable to be connected to the CN2L
connector of MR-J4-_A_-RJ.
0: Two-wire type
1: Four-wire type
Incorrect setting will trigger [AL. 70] and [AL. 71]. Setting "1" while using a servo
amplifier other than MR-J4-_A_-RJ will trigger [AL. 37].
0h
Содержание MR-J4-100A
Страница 9: ...A 8 MEMO ...
Страница 61: ...1 FUNCTIONS AND CONFIGURATION 1 44 MEMO ...
Страница 67: ...2 INSTALLATION 2 6 MEMO ...
Страница 137: ...3 SIGNALS AND WIRING 3 70 MEMO ...
Страница 261: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Страница 291: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 30 MEMO ...
Страница 299: ...8 TROUBLESHOOTING 8 8 MEMO ...
Страница 319: ...9 OUTLINE DRAWINGS 9 20 MEMO ...
Страница 461: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 36 MEMO ...
Страница 511: ...14 COMMUNICATION FUNCTION 14 38 MEMO ...
Страница 559: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Страница 583: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Страница 621: ...APPENDIX App 38 ...
Страница 639: ......