VS-50XL20U, VS-67XL20U, VS-50XLW20U
Set-up and Installation Manual
70
2.4. LED display
This product indicates the current status on “Status indicator” in the control
panel and “Warning LED” that lights blue on the screen.
•
Warning LED indication can be set in INDICATION menu (chapter
1.5.3.11, on page 24). You can erase the indication by [ESC] button in
remote control during LED lighting. [DISPLAY] button can restore the
setting. This LED turning off setting by remote control is effective until
the main power switch is shut down.
•
The status indicator shows the lamp operating time with 5-digit blinking
figure if you press [DISPLAY] button during power on or stand-by state.
LED display list
Status
Warning
LED
Status indicator
Reading
Memo
System initializing
Off
8
.
The last error indication can be restored even
if you turn off the main power switch.
Stand-by state
On
. (Dot)
After automatic shutdown, the last error
indication is retained in stand-by state
Start-up processing
Off
12345
It counts up according to the process. Error
status is cleared and re-checked.
In-service
(normal state)
Off
(None)
No signal
Off
- (Bar at
center)
Shutdown processing
Off
. (Blinking
dot)
Incorrect lamp attachment
or lamp door open
4
.
Just after detecting the failure, it turns off
automatically and enters stand-by state.
Lamp failure or lamp
burnout
Light
on 1 sec.
off 1 sec.
1
.
During retrying, the status indicator blinks. It
automatically goes to the lamp blowout mode.
Fan failure
0. (Zero)
During warning and shutdown processing, “0”
and the number that specifies defective fan
appear alternately.
30 seconds after detecting the failure, it
automatically turns off and retries once. Then it
enters stand-by state.
No.
Defective fan
1
Chassis cooling fan
2
Cube cooling fan
3 DMD
TM
chip cooling fan
4
Lamp cooling fan
5
Lamp power cooling fan
Power failure
Light
on 1 sec.
off 5 sec.
7
.
Color wheel failure
Lamp changer mechanical
failure(For VS-50XLW20U)
Light
on 5 sec.
off 1 sec.
5
.
30 seconds after detecting the failure, it
automatically turns off and retries once. Then it
enters stand-by state.
Lamp power circuit failure
(For VS-50XLW20U)
Off
9.
When the failure is detected, it automatically
turns off after cooling down, and retries once.
Then it enters stand-by state.
Firmware writing
Off
(None)
When you overwrite the firmware, set
dipswitch no. 2 OFF to change firmware
writing mode. After writing, set back the switch
and turn on the main switch again.
* The real error number shows continuously. Ignore numbers that appear only briefly.
* An error code many not indicate the primary cause. It may detect a secondary failure.
Warning LED
(Blue light on the right
center of the screen)