REV 1.4
37
1.6.5. Input
memory
saving
The adjusted values can be saved in the input memory. The number of memories is 128.
Note: Be sure to save newly adjusted signal even if the same resolution signal already exists in
the memory. If the FINE or POSITION, etc. settings are different from it, save the signal in
another input memory number.
[Procedure]
1. Press [ESC] button during the menu 1 displaying to show “SAVE THE CHANGES?”
message. And select YES in reply to it. To exit the menu without saving, select NO or press
[ESC].
2. Designate the memory number by left/right buttons and press [ENTER] button to save.
3. The current setting will be saved in the memory if the number is unregistered. If it has
already been registered, the overwrite confirmation message will be displayed.
4. If you don’t save it, press [ESC] button to exit the menu.
1.6.6. Input
memory
calling/deleting
Registered input memory can be called and deleted when needed.
•
Call: Press [MEM LIST] button and select INPUT MEMORY. Designate the memory number
to call by left/right buttons and press [ENTER] button.
•
Delete: Press [MEM LIST] button and select INPUT MEMORY. Designate the memory
number to delete by left/right buttons and press [ENTER] button. Select DELETE MEMORY