REV 1.4
25
1.5.3.12. AUTO POWER ON
Used to set automatic turning on when the main power is supplied. The initial setting is OFF.
•
ON
:
Automatic turning on when the main power is supplied.
•
OFF
:
When the main power is supplied, the projector uses the last memory status. For
instance, it becomes stand-by state if the main power was turned off in stand-by state.
Likewise, if it was turned off in the state of power on, it automatically turns on.
[Procedure]
1. Select AUTO POWER ON in MISC FUNCTION in the system menu.
2. Set ON or OFF.
1.5.3.13. BLOWOUT
Used to select the status after lamp blowout. The initial setting is OPERATE.
•
OPERATE
:
After lamp blowout, the functions that are required to operate multi-screen
system such as digital out, remote control and command control, etc. are maintained. Set
OPERATE when digital out is used in daisy-chained multi-screen.
•
SHUTDOWN
:
After lamp blowout, the projector starts protect shutdown. Set SHUTDOWN
in the case of a single screen or a multi-screen without the input board.
[Procedure]
1. Select BLOWOUT in MISC FUNCTION in the system menu.
2. Set OPERATE or SHUTDOWN.
1.5.3.14. LAMP CHANGER (for VS-50XLW20U)
CALIBRATION
This adjustment is normally unnecessary since it is automatically set in auto-lamp
changing (chapter 1.10.3, on page 59).
It adjusts the lamp position optimally to maximize the brightness.
[Procedure]
1. Select CALIBRATION in LAMP CHANGER in MAINTENANCE in the system menu.
2. Press [ENTER] button in reply to “SET OK?” message to adjust the lamp to the suitable
position automatically.
CHANGE MODE
Used to set the condition to start auto-lamp changing according to the brightness deterioration
detected by the luminous sensor (chapter 1.10.3.2, on page 59). The initial setting is NORMAL.
•
OFF: It does not perform auto-lamp changing due to the brightness deterioration.
•
NORMAL: Auto-lamp changing starts when the brightness becomes 50% of the initial value.
•
LONG: Auto-lamp changing starts when the brightness becomes 30% of the initial value.
[Procedure]
1. Select CHANGE MODE in LAMP CHANGER in MAINTENANCE in the system menu.
2. Set OFF, NORMAL or LONG.