- 3 -
Model
Power source
kW
*1
Heating capacity
kcal / h
BTU / h
kW
A
W.B
*1
(Nominal)
*1
Power input
Current input
Outdoor temp.
Temp. range of
W.B
-
-
-
heating
Inlet Water temp.
Circulating Water temp.
kW
*2
Cooling capacity
kcal / h
BTU / h
kW
A
D.B
*2
(Nominal)
*2
Power input
Current input
Outdoor temp.
Temp. range of cooling
D.B
-
Inlet Water temp.
Total capacity
Model / Quantity
Connectable
outdoor unit
/heat source unit
Sound pressure level (measured in anechoic room)
dB<A>
mm(in.)
mm(in.)
Diameter of
refrigerant pipe
mm(in.)
mm(in.)
Diameter of
water pipe
mm(in.)
mm
Field drain pipe size
External finish
External dimension H × W × D
in.
kg(lb)
Net weight
Circulating water
Range
Design pressure
Water
R410a
Drawing
Standard attachment
Optional parts
Remark
Note:
*2 Nominal cooling conditions (PWFY conditions are indicated in the parentheses.)
*1 Nominal heating conditions (PWFY conditions are indicated in the parentheses.)
Outdoor Temp. : 7°CDB/6°CWB (45°FDB / 43°FWB)
Outdoor Temp. : 35°CB (95°FDB)
kcal = kW × 860
BTU/h= kW × 3,412
Pipe length : 7.5 m (24-9/16 ft)
Pipe length : 7.5 m (24-9/16 ft)
Level difference : 0 m (0 ft)
Level difference : 0 m (0 ft)
<PUHY/PURY-series>
<PUHY/PURY-series>
Circulating water Temp. : 20°C (68°F)
Pipe length : 7.5 m (24-9/16 ft)
Level difference : 0 m (0 ft)
<PQHY/PQRY-series>
<PQHY/PQRY-series>
cfm = m
3
/min × 35.31
(Inlet water Temp 30°C
Water flow rate 2.15 m
3
/h)
(Inlet water Temp 30°C
Water flow rate 2.15 m
3
/h)
(Inlet water Temp 23°C
Water flow rate 1.93 m
3
/h)
Circulating water Temp. : 30°C (86°F)
Pipe length : 7.5 m (24-9/16 ft)
Level difference : 0 m (0 ft)
(Inlet water Temp 23°C
Water flow rate 1.93 m
3
/h)
* Install the unit in an environment where the
lb
= kg / 0.4536
* Due to continuing improvement, the above specifications may be subject to change without notice.
wet bulb Temp. will not exceed 32°C.
* The unit is not designed for outside installations.
* Please don't use the steel material for the water piping material.
* The water circuit must use the closed circuit.
* Please always make water circulate or add the brine to the circulation water when the ambient temperature becomes 0°C or less.
* Please always make water circulate or pull out the circulation water completely when not using it.
Inlet
Outlet
Operation Volume
Liquid
Gas
m
3
/h
MPa
MPa
Accessory
External
Wiring
Document
Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and
other items shall be referred to the Installation Manual.
Unit converter
* The specification data is subject
to rounding variation.
38,200
10~35°C (50~95°F)
0.015
Φ15.88 (Φ5/8") Brazed
Φ9.52 (Φ3/8") Brazed
PT3/4 Screw
Installation Manual, Instruction Book
PT3/4 Screw
NO
WKB94L763
0.068 - 0.065 - 0.063
50~100% of outdoor unit/heat source unit capacity
PUHY-(E)P
•
Y(S)JM-A(1)(-BS)
PUHY-HP
•
Y(S)HM-A(-BS)
PQHY-P
•
Y(S)HM-A
PURY-(E)P
•
Y(S)JM-A(1)(-BS)
PQRY-P
•
Y(S)HM-A
-5~43°C (23~110°F) PURY - series
-5~43°C (23~110°F) PUHY - series
0.6~2.15
1.00
Strainer, Heat insulation material, 2 × Connector sets
Φ32 (1-1/4'')
PWFY-P100VM-E-AU
1-phase 220-230-240V 50/60Hz
9,600
11.2
29
12.5
800 (785 without legs) × 450 × 300
WKE94C230
4.15
NONE
10,800
42,700
-20~15.5°C (-4~60°F) PUHY - series
10~45°C (50~113°F) PQRY - series
10~45°C (50~113°F) PQHY - series
-
-
Circulating Water temp.
10~45°C (50~113°F) PQRY - series
10~45°C (50~113°F) PQHY - series
10~40°C (50~104°F)
0.015
0.068 - 0.065 - 0.063
-20~32°C (-4~90°F) PURY - series
31-1/2" (30-15/16" without legs) × 17-3/4” × 11-13/16”
35 (78)
* Please do not use it as a drinking water.
* Please do not use groundwater and well water.
(2) PWFY-P100VM-E-AU