6
OCH668G
2
2-1. SYSTEM CONSTRUCTION
Remote
controller
Name
Model number
Functions
M-NET remote controller
PAR-F27MEA-E, PAR-U02MEDA
• A handy remote controller for use in
conjunction with the Melans centralized
management system.
• Addresses must be set.
• Addresses setting is not necessary.
MA remote controller
PAR-4xMAA, PAR-3xMAA ("x" represents 0 or later)
*
1
When the indoor unit of Fresh Air type is connected with the outdoor unit, the maximum connectable total indoor unit capacity is 110%.
*
2
For the PLFY-EP/VEM-E, up to 2 units can be connected . Other indoor units (Excluding the PEFY-P/ VMA3-E, PEFY-P/ VMH-E-F, and
PEFY-P
・
VMHS-E-F) can be connected within the total rated capacity and maximum number of connected units.
*
3
PUMY is connectable to Fresh Air type indoor unit.
It is possible to connect 1 Fresh Air type indoor unit to 1 outdoor unit. (1:1 system)
Operating temperature range (outdoor temperature) for fresh air type indoor units differ from other indoor units.
Refer to "2-4-(3). Operating temperature range".
*
4
Do not connect Lossnay remote controller(s). (PZ-61DR-E, PZ-60DR-E, PZ-52SF-E, PZ-43SMF-E)
*
5
Authorized connectable indoor units are as follows;
PUMY-SP112:PEFY-P25VMA3-E×2 + PEFY-P32VMA3-E×2
PUMY-SP125: PEFY-P25VMA3-E×1 + PEFY-P32VMA3-E×3
PUMY-SP140: PEFY-P32VMA3-E×2 + PEFY-P40VMA3-E×2
*
6
When connecting the CONNECTION KIT (PAC-LV11M-J) and an M-series indoor unit, refer to the installation manual for the CONNECTION KIT.
*
7
Connectable only for PUMY-SP▪VKMR1/R2.TH(-BS),PUMY-SP▪YKMR1/R2.TH(-BS).
*
8
Only for R2 models: PEFY-P·VMHS-E-F
OVERVIEW OF UNITS
Outdoor unit
4.5HP
5HP
6HP
SP112
SP125
SP140
Applicable
indoor unit
Capacity
Type 10 to Type 140
Number of units
1 to 12 units
1 to 12 units
1 to 12 units
Total system capacity range
50 to 130% of outdoor unit capacity
*
1
Branching pipe
components
Branch header
(2 branches)
Branch header
(4 branches)
Branch header
(8 branches)
CMY-Y62-G-E
CMY-Y64-G-E
CMY-Y68-G-E
M series remote
controller
Model
Capacity
Cassette Ceiling
Ceiling
concealed
Wall
Mounted
Ceiling
Suspended
Floor standing
Ceiling concealed
Lossnay
CONNECTION KIT
2 by 2
4-way flow
2-way flow 1-way flow
Exposed Concealed Fresh air
*3
Built-in
PAC-LV11M-J
PLFY-P PLFY-P PLFY-EP
*2
PLFY-M
PLFY-P PMFY-P
PEFY-P
PEFY-M
PKFY-P
PCFY-P PFFY-P PFFY-P
PEFY-P PDFY-P GUF
*4
10
–
–
–
–
–
–
–
–
10VLM-E/ET
–
–
–
–
–
–
15
15VFM-E1
–
–
–
–
–
15VMS1(L)-E
–
15VBM-E
15VLM-E/ET
–
–
–
–
–
–
20
20VFM-E1 20VBM-E
20VEM-E
–
20VEM-E/ET 20VLMD-E 20VBM-E
20VMS1(L)-E
20VMA(L)-E(2/3)
20VMR-E-L/R
20VMA(L)-A 20VBM-E
20VLM-E/ET
–
20VLEM-E
20VKM-E(2)
20VLRM-E
20VLRMM-E
20VCM-E
–
20VM-E
–
25
25VFM-E1 25VBM-E
25VEM-E
–
25VEM-E/ET 25VLMD-E 25VBM-E
25VMS1(L)-E
25VMA(L)-E(2/3)
25VMR-E-L/R
25VMA3-E
*5
25VMA(L)-A 25VBM-E
25VLM-E/ET
–
25VLEM-E
25VKM-E(2)
25VLRM-E
25VLRMM-E
25VCM-E
–
25VM-E
–
32
32VFM-E1 32VBM-E
32VEM-E
–
32VEM-E/ET 32VLMD-E 32VBM-E
32VMS1(L)-E
32VMA(L)-E(2/3)
32VMR-E-L/R
32VMA3-E
*5
32VMA(L)-A 32VHM-E
32VLM-E/ET
–
32VLEM-E
32VKM-E(2)
32VLRM-E
32VLRMM-E
32VCM-E
–
32VM-E
–
40
40VFM-E1 40VBM-E
40VEM-E
–
40VEM-E/ET 40VLMD-E 40VBM-E
40VMS1(L)-E
40VMA(L)-E(2/3)
40VMH(S)-E
40VMA3-E
*5
40VMA(L)-A 40VHM-E
40VLM-E/ET 40VKM-E
40VLEM-E
40VKM-E(2)
40VLRM-E
40VLRMM-E
40VCM-E
–
40VM-E
–
50
50VFM-E1 50VBM-E
50VEM-E 50VEM-E 50VEM-E/ET 50VLMD-E
–
50VMS1(L)-E
50VMA(L)-E(2/3)
50VMH(S)-E
50VMA(L)-A 50VHM-E
50VLM-E/ET
–
50VLEM-E
50VLRM-E
50VLRMM-E
50VCM-E
–
50VM-E 50RD(H)4
63
–
63VBM-E
63VEM-E 63VEM-E 63VEM-E/ET 63VLMD-E
–
63VMS1(L)-E
63VMA(L)-E(2/3)
63VMH(S)-E
63VMA(L)-A 63VKM-E
63VKM-E 63VLEM-E
63VLRM-E
63VLRMM-E
63VCM-E
–
63VM-E
–
71
–
–
–
–
–
–
71VMA(L)-E(2/3)
71VMH(S)-E
71VMA(L)-A
–
–
–
–
–
71VM-E
–
80
–
80VBM-E
80VEM-E 80VEM-E 80VEM-E/ET 80VLMD-E
–
80VMA(L)-E(2/3)
80VMH(S)-E
80VMA(L)-A
–
–
–
–
80VMH-E-F 80VM-E
–
100
–
100VBM-E
100VEM-E
–
100VEM-E/ET 100VLMD-E
–
100VMA(L)-E(2/3)
100VMH(S)-E 100VMA(L)-A 100VKM-E 100VKM-E
–
–
–
100VM-E 100RD(H)4
125
–
125VBM-E
125VEM-E
–
125VEM-E/ET 125VLMD-E
–
125VMA(L)-E(2/3)
125VMH(S)-E 125VMA(L)-A
–
125VKM-E
–
–
125VMHS-E-F
*8
125VM-E
–
140
–
–
–
–
–
–
140VMA(L)-E(2/3)
140VMH(S)-E 140VMA(L)-A
–
–
–
–
140VMH-E-F
–
–
M series indoor unit
*6
MSZ-GE Series
MSZ-SF Series
MSZ-EF Series
MSZ-FH Series
MSZ-LN Series
MFZ-KT Series
MSZ-AP Series
*7