53
OCH756
SW2 setting
Display detail
Explanation for display
Unit
The pipe temperature/Liquid (TH3)
−40 to 90
−40 to 90
(When the coil thermistor detects 0°C or below, “–”
and temperature are displayed by turns.)
Example: When −10°C
0.5 s 0.5 s 2 s
°C
The discharge temperature (TH4)
−20 to 217
−20 to 217
(When the discharge thermistor detects 100°C or
more, hundreds digit, tens digit and ones digit are
displayed by turns.)
Example: When 105°C
0.5 s 0.5 s 2 s
°C
The output step of outdoor FAN
0 to 16
0 to 16
Step
The number of ON/OFF times of com-
pressor
0 to 9999
0 to 9999
(When the number of times is 100 or more,
hundreds digit, tens digit and ones digit are
displayed by turns.)
Example: When 42500 times (425 ×100 times)
0.5 s 0.5 s 2 s
100
times
The compressor integrating operation
times
0 to 9999
0 to 9999
(When it is 100 hours or more, hundreds digit, tens
digit and ones digit are displayed by turns.)
Example: When 2450 hours (245 ×10 hours)
0.5 s 0.5 s 2 s
10 hours
The compressor operating current
0 to 50
0 to 50
Note: Value after the decimal point will be truncated.
A
The compressor operating frequency
0 to 255
0 to 255
(When it is 100 Hz or more, hundreds digit, tens
digit and ones digit are displayed by turns.)
Example: When 125 Hz
0.5 s 0.5 s 2 s
Hz
The LEV-A opening pulse
0 to 500
0 to 500
(When it is 100 pulse or more, hundreds digit, tens
digit and ones digit are displayed by turns.)
Example: When 150 pulse
0.5 s 0.5 s 2 s
Pulse
The error postponement code history (1)
of outdoor unit
Postponement code display
Blinking: During postponement
Lighting: Cancellation of postponement
“00” is displayed in the case of no postponement.
Code
display
The operation mode when the last error
occurred
This setting shows the operation mode when the last
error occurred as well as the default setting (Refer to
the following).
Code
display
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6
(SW2)
10
1
ON
2 3 4 5 6
1
05
4
25
2
45
1
25
1
50
1
ON
2 3 4 5 6
The black square (
■
) indicates a switch position.
Содержание PUD-SHWM100VAA
Страница 15: ...15 OCH756 5 OUTLINES AND DIMENSIONS Unit mm ...
Страница 17: ...17 OCH756 PUD SHWM140VAAR1 ...