62
OCH756
SW2 setting
Display detail
Explanation for display
Unit
The indoor liquid pipe temperature
(TH2) when the third-to-last error
occurred
−39 to 88
−39 to 88
Indoor liquid pipe temperature (TH2)
Σ(TH2(N))/n
(When it is 0 or less, “–” and numbers are displayed
by turns.)
°C
The indoor pipe temperature/Cond./Eva.
(TH5) when the third-to-last error
occurred
−39 to 88
−39 to 88
Indoor pipe temperature/Cond./Eva. (TH5)
Σ(TH5(N))/n
(When it is 0 or less, “–” and numbers are displayed
by turns.)
°C
The discharge temperature (TH4) when
the third-to-last error occurred
−20 to 217
−20 to 217
(When it is 0 or less, “–” and numbers are displayed
by turns.)
(When it is 100 or more, hundreds digit, tens digit
and ones digit are displayed by turns.)
°C
The outdoor liquid pipe temperature
(TH3) when the third-to-last error
occurred
−39 to 88
−39 to 88
(When it is 0 or less, “–” and numbers are displayed
by turns.)
°C
The outdoor 2-phase pipe temperature
(TH6) when the third-to-last error
occurred
−39 to 88
−39 to 88
(When it is 0 or less, “–” and numbers are displayed
by turns.)
°C
The ambient temperature (TH7) when
the third-to-last error occurred
−39 to 88
−39 to 88
(When it is 0 or less, “–” and numbers are displayed
by turns.)
°C
The heat sink temperature (TH8) when
the third-to-last error occurred
−40 to 200
−40 to 200
(When it is 0 or less, “–” and numbers are displayed
by turns.)
(When it is 100 or more, hundreds digit, tens digit
and ones digit are displayed by turns.)
°C
The suction pipe temperature (TH32)
when the third-to-last error occurred
−39 to 88
−39 to 88
(When it is 0 or less, “–” and numbers are displayed
by turns.)
°C
The Comp. surface temperature (TH33)
when the third-to-last error occurred
−20 to 217
−20 to 217
(When it is 0 or less, “–” and numbers are displayed
by turns.)
(When it is 100 or more, hundreds digit, tens digit
and ones digit are displayed by turns.)
°C
The LEV-A opening pulse when the
third-to-last error occurred
0 to 500
0 to 500
(When it is 100 or more, hundreds digit, tens digit
and ones digit are displayed by turns.)
Pulse
The LEV-B opening pulse when the
third-to-last error occurred
0 to 500
0 to 500
(When it is 100 or more, hundreds digit, tens digit
and ones digit are displayed by turns.)
Pulse
The LEV-C opening pulse when the
third-to-last error occurred
0 to 500
0 to 500
(When it is 100 or more, hundreds digit, tens digit
and ones digit are displayed by turns.)
Pulse
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6
The black square (
■
) indicates a switch position.
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6