![Mitsubishi Electric NZ2GF-CCB Скачать руководство пользователя страница 85](http://html.mh-extra.com/html/mitsubishi-electric/nz2gf-ccb/nz2gf-ccb_user-manual_1811813085.webp)
83
CHAPTER 9 TROUBLESHOOTING
9
9.
5 List
of
E
rror Codes and W
a
rn
ing
Codes
9.5
List of Error Codes and Warning Codes
This section describes error codes and warning codes.
9.5.1
Errors that occur in the bridge module
(1) Error codes
Error code
(hexadecimal)
Classification
Error
description
Action
0001
H
Major error
Bridge module
failure
Take noise reduction measures and reset the master station and the bridge
module.
If the same error occurs again, the hardware of the bridge module is in failure.
Please consult your local Mitsubishi representative.
0002
H
0003
H
0004
H
0006
H
CC-Link H/W error
0007
H
Data write error
0101
H
Moderate error
Data read error
Reset the bridge module.
If the same error occurs again, the hardware of the bridge module is in failure.
Please consult your local Mitsubishi representative.
0104
H
Date data out of
range
An error may have occurred due to noise or the hardware may be in failure. If
the same error occurs again even after measures have been taken against
noise, please consult your local Mitsubishi representative.
0107
H
Station number
switch out of range
Set a station number within the setting range.
0108
H
Data write error
Write the parameters again.
If the same error occurs again, the hardware of the bridge module is in failure.
Please consult your local Mitsubishi representative.
0109
H
Data read error
Reset the bridge module.
If the same error occurs again, the hardware of the bridge module is in failure.
Please consult your local Mitsubishi representative.
0511
H
Parameter not set
Set the startup mode switch to AUTO and set the switch to SET while the CC-
Link system is operating normally. Then set CC-Link parameters.
0512
H
Invalid parameter
Check if the same station numbers are used at the same time or the
connected CC-Link remote station supports only CC-Link Ver.2.
Содержание NZ2GF-CCB
Страница 1: ...CC Link IE Field Network CC Link Bridge Module User s Manual NZ2GF CCB ...
Страница 2: ......
Страница 9: ...7 Memo ...
Страница 35: ...33 CHAPTER 4 THE PROCEDURE BEFORE OPERATION 4 Memo ...
Страница 143: ...141 APPENDICES A Appendix 7 External Dimensions Appendix 7 External Dimensions 160 65 4 5 68 9 2 Unit mm ...
Страница 145: ...I 4 4 7 8 143 Memo ...
Страница 149: ......