FOR MULTI SYSTEM AIR CONDITIONER (MSZ-GS06/09/12/15/18/24)
OUTDOOR UNIT: MXZ series
Multi system air conditioner can connect 2 or more indoor units with 1 outdoor unit.
• When you try to operate 2 or more indoor units with 1 outdoor unit simultaneously, 1 for the cooling and the others
for heating, the operation mode of the indoor unit that operates first is selected. Other indoor units cannot operate,
and operation indicator lamp blinks as shown in the figure below. In this case, please set all the indoor units to the
same operation mode.
<Operation indicator lamp>
Lit
Blinking
Not lit
• When indoor unit starts the operation while the defrosting of outdoor unit is being done, it takes a few minutes
(max. 10 minutes) to blow out the warm air.
• In the heating operation, though indoor unit that does not operate may get warm or the sound of refrigerant flowing
may be heard, they are not malfunction. The reason is that the refrigerant continuously flows into it.
8-7. AUTO VANE OPERATION
1. Horizontal vane
(1) Vane motor drive
These models are equipped with a stepping motor for the horizontal vane. The rotating direction, speed, and angle of the
motor are controlled by pulse signals (approximately 12 V) transmitted from indoor microprocessor.
(2) The horizontal vane angle and mode change as follows by pressing VANE control button.
MSZ-GS30/36NA
MSY-GS30/36NA
MSZ-GS06/09/12/15/18/24NA
MSZ-GS30/36NA2
MSY-GS09/12/15/18/24NA
MSY-GS30/36NA2
AUTO
1
2
5
SWING
4
3
(3) Positioning
To confirm the standard position, the vane moves until it touches the vane stopper. Then the vane is set to the selected
angle.
(a) The operation starts or finishes (including timer operation).
(b) The test run starts.
(c) When standby mode (only during multi system operation) starts or finishes.
(4) VANE AUTO (
) mode
The microprocessor automatically determines the horizontal vane angle and operation to make the optimum room tem-
perature distribution.
MSZ-GS06/09/12/15NA
MSY-GS09/12/15NA
In COOL and DRY operation
FAN operation
(MSY)
Vane angle is fixed to Horizontal position.
In HEAT operation
(MSZ)
Vane angle is fixed to Angle 5.