MSZ-GS30NA2 MSZ-GS36NA2 MSY-GS30NA2 MSY-GS36NA2
7. Indoor electronic control P.C. board, switch P.C. board, display P.C. board, power monitor receiver P.C. board
Switch P.C. board
Power monitor receiver
P.C. board
Room temperature thermistor (RT11)
Indoor coil thermistor (RT12, RT13)
Temperature (°F)
Resistance (kΩ)
32 50 68 86 104 122 140
Vane motor
(CN151)
R111
12 V DC
GND
5 V DC
Indoor coil thermistor
RT12, RT13 (CN112)
Indoor electronic control P.C. board
Connector to Indoor
fan motor (CN211)
(+)3-6 V DC
15 V DC
(-) GND
(High voltage DC)
325 V DC
(+)0 or 15 V DC
To disable “Auto restart function”,
cut the Jumper wire to JR77.
(Refer to 7-3.)
Fuse (F11)
T3.15AL250V
Timer short
mode point
(Refer to 7-1.)
Varistor (NR11)
OBH874A