5 - 6
5. PARAMETERS
Classifi-
cation
No.
Symbol
Name and Function
Initial
Value
Unit
Setting
Range
20
INP
In-position range
Used to set the droop pulse range in which the in-position signal
(INP) will be output to the controller.
100
pulse
0
to
10000
21
MBR
Electromagnetic brake sequence output
Used to set a time delay between electromagnetic brake operation
and base drive circuit shut-off.
0
ms
0
to
1000
22
For manufacturer setting
Don't change this value by any means.
0001
23
*OP1
Optional function 1
Used to make the servo forced stop function invalid.
Servo forced stop selection
0: Valid
(Use the forced stop (EM1).)
1: Invalid
(Do not use the forced stop (EM1).)
Automatically switched on internally
0
0 0
0000
0000
to
0001h
24
*OP2
Optional function 2
Used to select slight vibration suppression control and motor-less
operation
Slight vibration suppression control selection
(Refer to Section 6.5.)
Made valid when auto tuning selection is
set to "0002" in parameter No.8.
Used to suppress vibration at a stop.
0: Invalid
1: Valid
Motor-less operation selection
0: Invalid
1: Makes motor-less operation valid.
When motor-less operation is made valid, signal output or
status display can be provided as if the servo motor is running
actually in response to the servo system controller command,
without the servo motor being connected.
Motor-less operation is performed as in the motor-less
operation using the servo configuration software.
(Refer to (d), (1) in Section 4.4.)
0
0
0000
0000
to
0010h
25
0000
Adj
u
st
me
n
t pa
ra
me
te
rs
26
For manufacturer setting
Don't change this value by any means.
0000
Содержание MR-J2-03B5
Страница 11: ...A 10 MEMO ...
Страница 15: ...4 MEMO ...
Страница 21: ...1 6 1 FUNCTIONS AND CONFIGURATION MEMO ...
Страница 27: ...2 6 2 INSTALLATION MEMO ...
Страница 61: ...5 8 5 PARAMETERS MEMO ...
Страница 73: ...7 2 7 INSPECTION MEMO ...
Страница 81: ...8 8 8 TROUBLESHOOTING MEMO ...
Страница 87: ...9 6 9 OUTLINE DIMENSION DRAWINGS MEMO ...
Страница 91: ...10 4 10 CHARACTERISTICS MEMO ...
Страница 111: ...11 20 11 OPTIONS AND AUXILIARY EQUIPMENT MEMO ...