11 - 13
11. OPTIONS AND AUXILIARY EQUIPMENT
11.2 Auxiliary equipment
Always use the devices indicated in this section or equivalent. To comply with the EN Standard or UL/C-
UL Standard, use the products which conform to the corresponding standard.
11.2.1 Recommended wires
(1) Wires for power supply wiring
The following diagram shows the wires used for wiring. Use the wires given in this section or
equivalent.
Servo amplifier
CNP2
CNP1
PE
24VDC power supply
AWG18 or AWG20
For the wire designed for motor cable,
refer to (2) in this section.
AWG18 or AWG20
Servo
motor
P24M
P24G
P24L
The wires used assume that they are 600V vinyl wires and the wiring distance is 30m(98.4ft) max. If
the wiring distance is over 30m(98.4ft), choose the wire size in consideration of voltage drop.
To comply with the UL/C-UL Standard, use UL-recognized copper wires rated at 60 (140 ) or more
for wiring.