3 - 13
3. SIGNALS AND WIRING
(3) Operation timings
(a) Servo-on command (from controller) ON/OFF
Tb [ms](parameter No.21) after the servo-on is switched off, the servo lock is released and the servo
motor coasts. If the electromagnetic brake is made valid in the servo lock status, the brake life may
be shorter. Therefore, when using the electromagnetic brake in a vertical lift application or the
like, set Tb to about the same as the electromagnetic brake operation delay time to prevent a drop.
Servo motor speed
Electromagnetic
brake (CNP2-9)
ON
OFF
Base circuit
Invalid (ON)
Valid (OFF)
ON
OFF
Servo-on command
(from controller)
Electromagnetic brake
operation delay time
Tb
Coasting
0 r/min
(60ms)
(80ms)
(b) Emergency stop command (from controller) or forced stop (EM1) ON/OFF
Servo motor speed
Electromagnetic
brake (CNP2-9)
ON
OFF
Base circuit
Invalid (ON)
Valid (OFF)
Emergency stop command
(from controller)
or
Forced stop (EM1)
(10ms)
(180ms)
(180ms)
Dynamic brake
Dynamic brake
Electromagnetic brake
Electromagnetic brake
Invalid (ON)
Valid (OFF)
Electromagnetic brake
operation delay time
Electromagnetic brake release
Содержание MR-J2-03B5
Страница 11: ...A 10 MEMO ...
Страница 15: ...4 MEMO ...
Страница 21: ...1 6 1 FUNCTIONS AND CONFIGURATION MEMO ...
Страница 27: ...2 6 2 INSTALLATION MEMO ...
Страница 61: ...5 8 5 PARAMETERS MEMO ...
Страница 73: ...7 2 7 INSPECTION MEMO ...
Страница 81: ...8 8 8 TROUBLESHOOTING MEMO ...
Страница 87: ...9 6 9 OUTLINE DIMENSION DRAWINGS MEMO ...
Страница 91: ...10 4 10 CHARACTERISTICS MEMO ...
Страница 111: ...11 20 11 OPTIONS AND AUXILIARY EQUIPMENT MEMO ...