1 - 2
1. FUNCTIONS AND CONFIGURATION
1.2 Servo amplifier standard specifications
Servo amplifier
Item
MR-J2-03B5
Voltage
21.6 to 30VDC (instantaneous permissible voltage 34V)
HC-AQ0135D
Continuous 0.8A, max. 2.4A
HC-AQ0235D
Continuous 1.6A, max. 4.8A
Circuit
power
supply
(Note)
Power supply
capacity
HC-AQ0335D
Continuous 2.4A, max. 7.2A
Control circuit power supply
(Note)
24VDC 10% 200mA (400mA when using the servo motor equipped with electromagnetic
brake)
System
Sine-wave PWM control, current control system
Dynamic brake
Built-in
Protective functions
Overcurrent shut-off, regenerative overvoltage shut-off, overload shut-off (electronic
thermal relay), servo motor overheat protection, encoder fault protection, undervoltage,
instantaneous power failure protection, overspeed protection, excessive error protection
Speed frequency response
250Hz or more
Structure
Open (IP00)
[ ]
0 to 55 (non-freezing)
Operation
[ ]
32 to 131 (non-freezing)
[ ]
20 to 65 (non-freezing)
Ambient
temperature
Storage
[ ]
4 to 149 (non-freezing)
Operation
Ambient
humidity
Storage
90%RH or less (non-condensing)
Ambient
Indoors (no direct sunlight)
Free from corrosive gas, flammable gas, oil mist, dust and dirt
Altitude
Max. 1000m (3280ft) above sea level
[m/s
2
]
5.9 or less
En
vi
ro
nm
en
t
Vibration
[ft/s
2
]
19.4 or less
[kg]
0.2
Weight
[lb]
0.44
Note: To comply with the low voltage directive, use a reinforced insulation stabilizing power supply.
1.3 Function list
The following table lists the functions of this servo. For details of the functions, refer to the reference field.
Function
Description
Reference
Slight vibration suppression
control
Suppresses vibration of 1 pulse produced at a servo motor stop.
Section 6.5
Real-time auto tuning
Automatically adjusts the gain to optimum value if load applied to the servo
motor shaft varies.
Section 6.2
Section 6.3
Parameter No.9
Torque limit
Servo motor torque can be limited to any value.
Parameter No.10
Parameter No.11
External forced stop signal
automatic ON
Forced stop (EM1) can be automatically switched on internally to invalidate it. Parameter No.23
Test operation mode
Servo motor can be run from the operation section of the servo amplifier
without the start signal entered.
Section 4.4
Servo configuration software
Using a personal computer, parameter setting, test operation, status display,
etc. can be performed.
Section 11.1.2
Содержание MR-J2-03B5
Страница 11: ...A 10 MEMO ...
Страница 15: ...4 MEMO ...
Страница 21: ...1 6 1 FUNCTIONS AND CONFIGURATION MEMO ...
Страница 27: ...2 6 2 INSTALLATION MEMO ...
Страница 61: ...5 8 5 PARAMETERS MEMO ...
Страница 73: ...7 2 7 INSPECTION MEMO ...
Страница 81: ...8 8 8 TROUBLESHOOTING MEMO ...
Страница 87: ...9 6 9 OUTLINE DIMENSION DRAWINGS MEMO ...
Страница 91: ...10 4 10 CHARACTERISTICS MEMO ...
Страница 111: ...11 20 11 OPTIONS AND AUXILIARY EQUIPMENT MEMO ...