13
e.g.) Compressor’s rotational speed 56rps, Fan box fan ON
Blinking
“ ”
Lighting
Fan in box fan ON/OFF
Compressor’s
rotational speed
Tens’ place
Compressor’s
rotational speed
Ones’ place
Display during Compressor’s
rotational speed change mode
Room display
Corresponding
values
8
4
2
1
Ice making mode
display
Corresponding
values
8
4
2
1
Blinking
“ ”
Lighting
Fan in box fan ON
Tens’ place "5"
(=4+1)
Ones’ place "6"
(=4+2)
Display during Compressor’ s
rotational speed change mode
Changing the rotational speed
After setting this mode, compressor’s rotational speed changes every time
button is pressed.
Rotational speed (rps) is divided into ones’ place and tens’ place when it is displayed.
(Basically the compressor starts operation at level 10, however, it may be different depending on models, or as a result of
specification change.)
<Change of rotational speed>
Rotational speed can be changed only when the compressor is in operation. While the compressor stops, rotational speed is
not displayed, and
button operation is not effective. When the compressor stops, unplug the power code, and wait for
a several minutes, then plug it again.
Operation sound may get increase in the process of changing rotational speed, but that is not dysfunction. Check the sound
level when rotational speed is stabilized.
Switching ON/OFF the box fan
In this mode, box fan can be switched on and off at each press of
.
Box fan
The ON/OFF state is displayed with on the display panel.
ON
OFF
Display of
Lighting
Not lighting
2) Compressor’s rotational speed change mode
Setting
With the ice making compartment’s door opened, simultaneously press
and
for 3 seconds until a “beep”
sound is heard.
starts to blink.
With the door opened, press
for 3 seconds to start compressor’s rotational speed change mode.
Once this mode starts, it continues operating even if the door is closed.
Compressor’s rotational speed change mode is not available during demonstration mode, thermistor temperature check
mode, set temperature adjustment mode, error history display mode, or when child lock is effective.
Display during compressor’s rotational speed change mode
During compressor’s rotational speed change mode, blinks and
lights up.
Display of rotational speed
• Compressor’s rotational speed is divided into ones’ place and tens’ place when it is displayed.
• One of the values (8/4/2/1) is assigned to each indicator of both tens’ place and one’ place on the display panel. The sum of
the corresponding values of the lighting indicators is the compressor’s rotational speed.
Level 0
Level 1
Level 2
Level 3
Level 4
Level 5
Normal
Low speed
High speed
Level 6
Level 7
Level 8
Level 9
Level 10