58
1 SERVO PARAMETER DETAILS
1.4 Extension setting servo parameters group ([Pr. PC_ _ ])
[Pr. PC19_Function selection C-6 (*COP6)]
[Pr. PC19.0_[AL. 099 Stroke limit warning] selection]
Enable or disable [AL. 099 Stroke limit warning].
When "Disabled" is selected, [AL. 099] does not occur while LSP (Forward rotation stroke end) or LSN (Reverse rotation
stroke end) is off, but the operation will be stopped with the stroke limit.
0: Enabled
1: Disabled
[Pr. PC19.4_Output open-phase detection selection]
Enable or disable the detection of output open-phase detection function.
0: Disabled
1: Enabled
[Pr. PC19.6_Output open phase - Judgment speed selection]
0: Servo motor speed
1: Speed command
When "0" (servo motor speed) is set, the value of the servo motor speed is used for the speed judgment of the output open-
phase detection.
When "1" (speed command) is set, the speed command value is used for the speed judgment of the output open-phase
detection.
In the torque mode, set "0" (servo motor speed). When "1" (speed command) is set, [AL. 139.2 Output open-phase error]
does not occur.
[Pr. PC20_Function selection C-7 (*COP7)]
[Pr. PC20.2_Undervoltage alarm selection]
Select the alarm or warning that occurs when the bus voltage drops to the undervoltage alarm trigger level.
0: [AL. 010 Undervoltage] occurs regardless of servo motor speed
1: [AL. 0E9 Main circuit off warning] occurs when the servo motor speed is 50 r/min (50 mm/s) or less, and [AL. 010] occurs
when over 50 r/min (50 mm/s).
Initial value
Setting range
Ver.
00000000h
Refer to the relevant detail No.
Refer to the relevant detail No.
Initial value
Setting range
Ver.
0h
Refer to the text
A4
Initial value
Setting range
Ver.
0h
Refer to the text
A4
Initial value
Setting range
Ver.
0h
Refer to the text
A4
Initial value
Setting range
Ver.
00000000h
Refer to the relevant detail No.
Refer to the relevant detail No.
Initial value
Setting range
Ver.
0h
Refer to the text
A4
Содержание MELSERVO MR-JET-G Series
Страница 1: ...MR JET G User s Manual Parameters MR JET _G MR JET _G N1 Mitsubishi Electric AC Servo System ...
Страница 2: ......
Страница 148: ...146 4 SERVO PARAMETER SETTING METHOD 4 2 Object dictionary MEMO ...
Страница 159: ...6 NETWORK PARAMETER SETTING METHOD 6 1 Engineering tool 157 6 MEMO ...
Страница 163: ......