110
1 SERVO PARAMETER DETAILS
1.9 Positioning control setting servo parameters group ([Pr. PT_ _])
[Pr. PT68_Function selection T-11 (**TOP11)]
[Pr. PT68.0_Quick stop method selection]
Select the quick stop method.
2: Servo-off after Quick stop
This function corresponds to [Quick stop option code (Obj. 605Ah)].
When the object is mapped to the cyclic communication, do not write values with engineering tools because the controller
overwrites the servo parameter values written with engineering tools.
[Pr. PT68.2_Temporary stop method selection]
Select a temporary stop method.
0: Automatic selection (deceleration to a stop method)
1: Deceleration to a stop method
This function corresponds to [Halt option code (Obj. 605Dh)].
When the object is mapped to the cyclic communication, do not write values with engineering tools because the controller
overwrites the servo parameter values written with engineering tools.
Initial value
Setting range
Ver.
00000002h
Refer to the relevant detail No.
Refer to the relevant detail No.
Initial value
Setting range
Ver.
2h
Refer to the text
A4
Initial value
Setting range
Ver.
0h
Refer to the text
A4