1 SERVO PARAMETER DETAILS
1.11 Positioning extension setting servo parameters group ([Pr. PV_ _ ])
113
1
1.11
Positioning extension setting servo parameters
group ([Pr. PV_ _ ])
[Pr. PV01_Profile speed command extension setting (PVC2)]
Set the speed command used in the profile position mode (pp).
The unit is [pulse/s].
This function is enabled when [Pr. PT01.1 Speed/acceleration/deceleration unit selection] is set to "1". This function and [Pr.
PT65 Profile speed command] are mutually exclusive.
The setting value will be clamped at the maximum speed. When changing the speed to the permissible speed, set the speed
in [Pr. PA28.4 Speed range limit selection].
This function corresponds to [Profile velocity (Obj. 6081h)].
When the object is mapped to the cyclic communication, do not write values with engineering tools because the controller
overwrites the servo parameter values written with engineering tools.
[Pr. PV03_Maximum profile speed extension setting (MPVCE)]
Set the speed limit value of the profile position mode (pp) and the profile velocity mode (pv).
The unit is [pulse/s].
This function is enabled when [Pr. PT01.1 Speed/acceleration/deceleration unit selection] is set to "1". This function and [Pr.
PT66 Maximum profile speed] are mutually exclusive.
This function corresponds to [Max profile velocity (Obj. 607Fh)].
When the object is mapped to the cyclic communication, do not write values with engineering tools because the controller
overwrites the servo parameter values written with engineering tools.
[Pr. PV05_Profile acceleration (PACC)]
Set the acceleration used in the profile position mode (pp) and the profile velocity mode (pv).
The unit is [pulse/s
2
].
When the setting value of this servo parameter is "0", the servo motor accelerates in accordance with the time constant set in
[Pr. PT49 Speed acceleration time constant].
This function is enabled when [Pr. PT01.1 Speed/acceleration/deceleration unit selection] is set to "1". This function and [Pr.
PT49] are mutually exclusive.
This function corresponds to [Profile acceleration (Obj. 6083h)].
When the object is mapped to the cyclic communication, do not write values with engineering tools because the controller
overwrites the servo parameter values written with engineering tools.
Initial value
Setting range
Ver.
0 [Refer to the text below for the unit.]
0 to 4294967295
B2
Initial value
Setting range
Ver.
2147483647 [Refer to the text below for the unit.]
0 to 4294967295
B2
Initial value
Setting range
Ver.
0 [Refer to the text below for the unit.]
0 to 4294967295
B2
Содержание MELSERVO MR-JET-G Series
Страница 1: ...MR JET G User s Manual Parameters MR JET _G MR JET _G N1 Mitsubishi Electric AC Servo System ...
Страница 2: ......
Страница 148: ...146 4 SERVO PARAMETER SETTING METHOD 4 2 Object dictionary MEMO ...
Страница 159: ...6 NETWORK PARAMETER SETTING METHOD 6 1 Engineering tool 157 6 MEMO ...
Страница 163: ......